4. Align and attach the fluid cover to lock the
diaphragm in place. NOTE: You must use
the fluid cover that has the install tools (AC)
attached to the inlet and outlet ports. (See
Disassemble the Fluid Section, page 21
.)
To tighten the bolts, see
.
5. Supply shop air at about 20 psi (0.14 MPa,
1.4 bar). Do not use over 30 psi (0.21 MPa,
2.1 bar). The shaft will move to one side.
6. Torque the exposed shaft to 100–120 in-lb
(11–14 N•m) using a 3/4 in. claw foot wrench.
7. Leave the air on. Install the other diaphragm
assembly (diaphragm, air plate, and washer, if
used). Use both hands and install as tight as
possible by hand.
8. Align and attach the second fluid cover. To tighten
the bolts, see
.
9. Remove the diaphragm tools (AC) and the
o-rings (38).