meter
outlet
Fig. 4
8241C
6c
6a
6b
5a
5c
5b
6d
7a
7c
7c
7c
7d
7b
7b
7a
7c
This flexible extension
can also be threaded
directly into the meter outlet
without the street elbow
(6d) or sealing nut (6c).
7d
nozzle bushing
nozzle bushing
Either end of this rigid
tube can be threaded into
the meter outlet. This is
the best orientation for use
with a dispense console.
6
308487
Installation
10.
Model 238457
See Fig. 4.
a.
Thread the sealing nut (5c) onto the exten-
sion (5a) with the PTFE side facing out.
b.
Thread the extension (5a) into the meter outlet
at least three full turns, position it for proper
alignment, and tighten the sealing nut against
the meter outlet.
Model 238458
See See Fig. 4.
a.
Thread the sealing nut (6c) onto the elbow (6d)
with the PTFE side facing out.
b.
Thread the elbow (6d) into the meter outlet at
least three full turns, position it for proper
alignment, and tighten the sealing nut (6c)
against the meter outlet.
c.
Thread the flexible hose (6a) into the elbow,
and tighten it.
NOTE:
The flexible hose (6a) can also be
threaded directly into the meter outlet without
the elbow or sealing nut.
Model 238459
This nozzle assembly can be configured two ways.
See See Fig. 4.
a.
Thread a sealing nut (7c) onto the tube (7a)
with the PTFE side facing out.
b.
Thread the tube (7a) into the meter outlet at
lease three full turns, position it for proper
alignment, and tighten the sealing nut (7c)
against the meter outlet.
c.
Thread the other sealing nut (7c) onto the
other end of the tube (7a) with the PTFE side
facing out.
d.
Thread the elbow (7d) onto the end of the tube
(7a) at least full turns, position it for proper
alignment, and tighten the sealing nut (7c)
against the elbow.
OR
a.
Thread a sealing nut (7c) onto the elbow (7d)
with the PTFE side facing out.
b.
Thread the elbow (7d) into the meter outlet at
lease three full turns, position it for proper
alignment, and tighten the sealing nut (7c)
against the meter outlet.
c.
Thread the other sealing nut (7c) onto the
tube (7a) with the PTFE side facing out.
d.
Thread the tube (7a) into the elbow (7d) at
least three full turns, position it for proper
alignment, and tighten the sealing nut (7c)
against the elbow (7d).
Содержание EM5 238457