Parts
EQs2
EQs2
EQs2 (continued)
(continued)
(continued)
1.
Apply thread sealant to all non-swivel pipe
threads.
2
Apply anti-seize to threads.
3
Torque to 60 +/-5 ft-lb (81.3 +/- 6.7 N•m)
with pot pressurized.
4
Torque to 15 +/-2 ft-lb (20.3 +/- 2.7 N•m).
5
Apply anti-seize to enclosure mounting
studs.
6
Torque to 25–30 ft-lb (34–40.6 N•m).
7
The handway gasket must be assembled
centered and flat on the handway cover.
8
Apply anaerobic sealant to threads.
42
3A3489E