1.
Apply thread sealant to all non-swivel pipe
threads.
2
Apply anti-seize to threads.
3
Torque to 60 +/-5 ft-lb (81.3 +/- 6.7 N•m)
with the pot pressurized.
4
Torque to 15 +/-2 ft-lb (20.3 +/- 2.7 N•m)
5
Apply anaerobic sealant to threads.
6
The handway gasket must be assembled
centered and flat on the handway cover.