Spray
3A6917A
13
Spray
1.
Follow the
on page 11.
2.
Follow the
on page 10.
3.
Install tip and tip guard onto gun. Close the drain
valve.
4.
Turn power switch (E) ON.
5.
Pull out and turn pressure adjustment knob (H) until
desired pressure is reached. Turn clockwise to
increase pressure, counterclockwise to decrease
pressure. Push knob in to lock.
6.
Disengage the gun trigger lock.
7.
Spray a test pattern. Read fluid manufacturer
recommendations and adjust as necessary.
NOTE:
When determining the desired spray
pressure, always increase the spray pressure until
the spray pattern fully develops. This will reduce the
pressure surge when the pump is stalled and
minimize over-spray.
*The sprayer can stall at pressures higher than the
dynamic pressure. All components downstream of
the sprayer must be rated for the pressures listed in
on page 27.
8.
Flush when finished spraying. Follow the
on page 11.
9.
Follow the
on page 10.
NOTICE
Do not allow pump to run dry. It will quickly accelerate
to a high speed causing damage.
WLD
ON
E
WLD
H
Pressure
Adjustment Knob
Setting
Dynamic Pump Outlet
Pressure
psi
Bar
MPa
1
500
35
3.5
2
1000
69
6.9
3
1500
103
10.3
4
2000
138
13.8
5
2500
172
17.2
6
3000
207
20.7
7
3500
241
24.1
8
4000
276
27.6
9
4500
310
31.0
10
*5000
*345
*34.5