Setup
12
3A6917A
7.
If priming, equipment is now ready to spray
(proceed to Spray, page 15). If flushing, proceed
with step 8.
NOTE:
The remaining steps are for flushing only.
8.
Follow the
on page 10.
9.
Turn power switch (E) ON. To start pump, pull out
pressure adjustment knob (H) and turn clockwise
slowly to increase pressure, until a steady stream
flows from drain valve. Push knob in to lock.
NOTE:
To determine the proper amount of solvent
and flushing time, remove the inlet valve housing to
verify it has been fully cleaned, especially when
spraying a new material for the first time.
10. Wait for clean solvent to flow from drain tube.
11. Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
12. Turn power switch (E) OFF.
13. Check the pump and gun filters.
NOTICE
Do not prime pump through drain/purge valve using
two component materials. Mixed two-component
materials will harden in valve and result in clogging.
WLD