Prime/Flush
333208F
11
Prime/Flush
1. Perform
2. Remove tip and tip guard from gun.
3. Place material supply suction hose into compatible
fluid (if priming) or solvent (if flushing).
4. Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
5. Turn power switch (E) ON.
6. Prime or flush hose and gun:
a. Disengage gun trigger lock.
b. Trigger gun into grounded pail. Pull out
pressure adjustment knob (H) and turn
clockwise slowly to increase pressure, until a
steady stream flows from gun. Push knob in to
lock.
If flushing
, trigger gun for 10-15 seconds.
c. Engage trigger lock.
7. If priming, equipment is now ready to spray
(proceed to
Spray
, page 12). If flushing, proceed
with step 8.
NOTE:
The remaining steps are for flushing only.
8. Place drain tube in a grounded waste pail.
9. Slightly rotate drain/purge valve handle (C)
counterclockwise to open.
10. To start pump, pull out pressure adjustment knob
(H) and turn clockwise until pump begins to move.
Push knob in to lock.
11. When clean solvent flows from drain tube, rotate
drain/purge valve handle (C) clockwise to close.
Pump will stall.
12. Perform
Leave solvent in and store sprayer.
To avoid injury from splashing, always flush at lowest
possible pressure.
H
ti20171a_1
WLE
21
E
ti5048b
ti8727a
NOTICE
Do not prime pump through drain/purge valve using
two component materials. Mixed two-component
materials will harden in valve and result in clogging.
WLLD
C
H
ti20171a_1
WLD
C