![Graco E-Flo EM0011 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/graco/e-flo-em0011/e-flo-em0011_instructions-and-installation-manual_2251329015.webp)
Operation
Flow
Flow
Flow Mode
Mode
Mode
When in flow mode, the motor will maintain a
constant speed regardless of the fluid pressure, up
to the pump’s maximum working pressure. See
Technical Data, page 25
.
1.
Turn the Control Knob (N) fully counterclockwise
to 0.
2.
Pull the Mode Select switch (M) out to set. Turn
the switch to Flow
. Push the switch in to
lock.
3.
The amount of flow is determined by the cycle
rate set with the Control Knob (N). The knob’s
scale (0–10) corresponds to a cycle adjustment
range of 0-30 cycles per minute. Turn the Control
Knob (N) clockwise to increase the cycle rate
(flow), or counterclockwise to decrease the cycle
rate (flow).
Figure 13 Flow Mode
3A2526L
15