Installation
Installation
Installation
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.
Location
Location
Location
When selecting the location for the equipment, keep
the following in mind:
• There must be sufficient space on all sides of
the equipment for installation, operator access,
maintenance, and air circulation.
• Ensure that the mounting surface and mounting
hardware are strong enough to support the weight
of the equipment, fluid, hoses, and stress caused
during operation.
• There must be a start/stop control (C) within easy
reach of the equipment. See Fig. 1.
Mount
Mount
Mount the
the
the Pump
Pump
Pump
See
Mounting Hole Patterns, page 23
Secure the stand to the floor with M19 (5/8 in.)
bolts which engage at least 152 mm (6 in.) into the
concrete floor to prevent the pump from tipping.
Level the pump as required, using shims.
Power
Power
Power Supply
Supply
Supply Requirements
Requirements
Requirements
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
National, State and Local safety and fire codes.
See Table 1 for power supply requirements. The
system requires a dedicated circuit protected with a
circuit breaker.
Table
Table
Table 1
1
1 ... Power
Power
Power Supply
Supply
Supply Specifications
Specifications
Specifications
Model
Model
Model
Voltage
Voltage
Voltage
Phase
Phase
Phase
Hz
Hz
Hz
Current
Current
Current
EM0011
EM0012
100–250
Vac
1
50/60
20 A
EM0021
EM0022
200–250
Vac
1
50/60
20 A
Hazardous
Hazardous
Hazardous Area
Area
Area Cabling
Cabling
Cabling and
and
and Conduit
Conduit
Conduit
Requirements
Requirements
Requirements
Explosion
Explosion
Explosion Proof
Proof
Proof
All electrical wiring in the hazardous area must be
encased in Class I, Division I, Group D approved
explosion-proof conduit. Follow all National, State,
and Local electric codes.
A conduit seal (D) is required within 18 in. (457 mm)
of the motor for the US and Canada. See Fig. 3.
All cables must be rated at 70°C (158°F).
Flame
Flame
Flame Proof
Proof
Proof (ATEX)
(ATEX)
(ATEX)
Use appropriate conduit, connectors, and cable
glands rated for ATEX II 2 G. Follow all National,
State, and Local electric codes.
All cable glands and cables must be rated at 70°C
(158°F).
8
3A2096D
Содержание E-Flo EC1110
Страница 7: ...Notes Notes Notes Notes 3A2096D 7...
Страница 28: ...Notes Notes Notes Notes 28 3A2096D...