background image

Warnings

Warnings

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The

exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING

WARNING

WARNING

FIRE

FIRE

FIRE AND

AND

AND EXPLOSION

EXPLOSION

EXPLOSION HAZARD

HAZARD

HAZARD

Flammable fumes, such as solvent and paint fumes, in work

work

work area

area

area can ignite or explode. To help

prevent fire and explosion:

• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable

fumes are present.

• Ground all equipment in the work area. See Grounding

Grounding

Grounding instructions.

• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless

they are antistatic or conductive.

• Stop

Stop

Stop operation

operation

operation immediately

immediately

immediately if static sparking occurs or you feel a shock, Do not use

equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

Static charge may build up on plastic parts during cleaning and could discharge and ignite
flammable vapors. To help prevent fire and explosion:

• Clean plastic parts only in well ventilated area.

• Do not clean with a dry cloth.

• Do not operate electrostatic guns in equipment work area.

ELECTRIC

ELECTRIC

ELECTRIC SHOCK

SHOCK

SHOCK HAZARD

HAZARD

HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can
cause electric shock.

• Turn off and disconnect power at main switch before disconnecting any cables and before

servicing or installing equipment.

• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes

and regulations.

BURN

BURN

BURN HAZARD

HAZARD

HAZARD

Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid
severe burns:

• Do not touch hot fluid or equipment.

4

3A2096D

Содержание E-Flo EC1110

Страница 1: ...n circulation circulation applications applications applications For For For professional professional professional use use use only only only Important Important Important Safety Safety Safety Instru...

Страница 2: ...Module Accessory 12 Operation 13 Startup 13 Shutdown 13 Pressure Relief Procedure 13 Maintenance 14 Preventive Maintenance Schedule 14 Change the Oil 14 Check Oil Level 14 Bearing Pre Load 14 Flushin...

Страница 3: ...d and and Controls Controls Controls 1 1 1 2 2 2 3 3 3 or or or 4 4 4 Pump Pump Pump Type Type Type and and and Fittings Fittings Fittings 1 1 1 2 2 2 or or or 3 3 3 Mounting Mounting Mounting Type Ty...

Страница 4: ...rounding Grounding instructions Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Sto...

Страница 5: ...ensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately...

Страница 6: ...o not leave the work area while equipment is energized or under pressure Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipm...

Страница 7: ...Notes Notes Notes Notes 3A2096D 7...

Страница 8: ...njury if work is not performed properly Have a qualified electrician perform any electrical work Be sure your installation complies with all National State and Local safety and fire codes See Table 1...

Страница 9: ...e in hazardous locations B Fused Safety Switch with lock C Start Stop Control must be approved for use in hazardous locations D Explosion Proof Conduit Seal Required within 18 in 457 mm of the motor f...

Страница 10: ...t stop control must be approved for use in hazardous locations 3 Open the electrical compartment S on the motor 4 Bring the power wires into the electrical compartment through the 3 4 14 npt f inlet p...

Страница 11: ...E NOTE Advanced models require installation of the 24P822 Control Module All pumps connected to a common control module must be grounded to the same ground point Different ground points unequal potent...

Страница 12: ...silicone free synthetic gear oil Check the oil level in the sight glass K Fill until the oil level is near the halfway point of the sight glass The oil capacity is approximately 1 5 quarts 1 4 liters...

Страница 13: ...es are primed and all air is forced out of the system Shutdown Shutdown Shutdown Follow the Pressure Relief Procedure page 13 Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Proced...

Страница 14: ...near the halfway point of the sight glass The oil capacity is approximately 1 5 quarts 1 4 liters Do Do Do not not not overfill overfill overfill 4 Reinstall the fill cap Figure 6 Oil Drain Plug Check...

Страница 15: ...n both strokes Worn piston packing Replace See lower manual Held open or worn ball check valves Check and repair See lower manual Pump output low on only one stroke Worn piston packing Replace See low...

Страница 16: ...mbly Reassembly Reassembly NOTE NOTE NOTE If the coupling adapter 9 and tie rods 6 have been disassembled from the motor see Reassemble the Coupling Adapter and Tie Rods to the Motor page 17 1 See Fig...

Страница 17: ...led from the motor to ensure proper alignment of the motor shaft to the piston rod R 1 See Fig 7 Screw the tie rods 6 into the motor 3 and torque to 50 60 ft lb 68 81 N m 2 Screw the coupling adapter...

Страница 18: ...Parts Parts Parts Parts Pump Pump Pump Assembly Assembly Assembly See Models page 3 for an explanation of the pump part number 18 3A2096D...

Страница 19: ...and 3b 1 3a 16M130 LABEL warning 1 3b 16W645 OIL gear synthetic ISO 220 silicone free 1 quart 0 95 liter not shown 2 4 See Pump Matrix page 20 WASHER 4 5 See Pump Matrix page 20 BOLT 4 6 15G924 ROD ti...

Страница 20: ...C2210 A EM0012 24F424 EC2211 A 255143 256193 EM0012 100133 100101 24F424 EC2212 A 255143 EM0012 100133 100101 24F424 EC2310 A EM0021 24F424 EC2311 A 255143 256193 EM0021 100133 100101 24F424 EC2312 A...

Страница 21: ...435 EC3331 A 255143 256193 EM0021 100133 100101 24F435 EC3332 A 255143 EM0021 100133 100101 24F435 EC3430 A EM0022 24F435 EC3431 A 255143 256193 EM0022 100133 100101 24F435 EC3432 A 255143 EM0022 1001...

Страница 22: ...Dimensions Dimensions Dimensions Dimensions A A A B B B C C C D D D 58 00 in 1473 mm 17 00 in 432 mm 45 50 in 1156 mm 19 88 in 505 mm 22 3A2096D...

Страница 23: ...ng Mounting Hole Hole Hole Patterns Patterns Patterns Floor Floor Floor Stand Stand Stand Dimension Dimension Dimension Measurement Measurement Measurement A 19 88 in 505 mm B 14 50 in 368 mm C 16 88...

Страница 24: ...ment A 17 8 in 451 mm B 14 5 in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Fo...

Страница 25: ...e charts show the motor operating at 100 70 and 40 of maximum force These values are approximately equivalent to an air motor operating at 100 70 and 40 psi 100 of maximum force 70 of maximum force 40...

Страница 26: ...tions FLUID FLUID FLUID PRESSURE PRESSURE PRESSURE psi bar MPa FLUID FLUID FLUID FLOW FLOW FLOW gpm lpm Table Table Table 4 4 4 Models Models Models EC23xx EC23xx EC23xx and and and EC24xx EC24xx EC24...

Страница 27: ...tions FLUID FLUID FLUID PRESSURE PRESSURE PRESSURE psi bar MPa FLUID FLUID FLUID FLOW FLOW FLOW gpm lpm Table Table Table 6 6 6 Models Models Models EC43xx EC43xx EC43xx and and and EC44xx EC44xx EC44...

Страница 28: ...Notes Notes Notes Notes 28 3A2096D...

Страница 29: ...cc bar Models ECx3xx and ECx4xx 436000 v volume of lower in cc psi 3000 v volume of lower in cc bar Maximum continuous cycle rate 20 cpm Maximum Flow Maximum flow is determined by the size of the pump...

Страница 30: ...ARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AN...