background image

Instructions, Repair and Parts

Dyna-Star

®

 HP 

Pump System

332540B

Provides lubricant flow and pressure to operate a single line parallel automatic lubrication 
system. For automatic lubrication systems only. 
Not approved for use in explosive atmospheres or hazardous locations. 

Graco Tank Injector Lubrication Systems

3500 psi (24.1 MPa, 241 bar) Maximum Working 
Pressure

Models

All models include Tube-in-Tube design, vent valve, 
cover and tank.

Important Safety Instructions
Read all warnings and instructions in this 
manual and the Dyna-Star HP and HF 
Pump instruction manual. Save all 
instructions.

System

Models

Size

Dip 

Stick

35/60 

Pound

90/120 
Pound

77X100

X

X

77X101

X

X

EN

Содержание Dyna-Star 77X100

Страница 1: ...ve atmospheres or hazardous locations Graco Tank Injector Lubrication Systems 3500 psi 24 1 MPa 241 bar Maximum Working Pressure Models All models include Tube in Tube design vent valve cover and tank...

Страница 2: ...s including rags and spilled or open containers of solvent and gasoline Do not plug or unplug power cords or turn lights on or off when flammable fumes are present Ground all equipment in the work are...

Страница 3: ...ipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifi...

Страница 4: ...MENT Wear appropriate protective equipment when in the work area to help prevent serious injury including eye injury hearing loss inhalation of toxic fumes and burns This protective equipment includes...

Страница 5: ...t your needs Key A Lubricant outlet connection B Pump C Ignition switch D High pressure lubricant supply lines E Injector banks F Lubrication controller G Fill port H Overflow port J Breather K Reserv...

Страница 6: ...maximum working pressure of each component in the system may not be the same To reduce the risk of overpressurizing any component in the sys tem be sure you know the maximum working pres sure of each...

Страница 7: ...t port marked 0 on the vent valve When de energized it vents pressure inter nally to tank Refer to the Dyna Star HP or HF Vent Valve Kit manual 332515 for installation and operation instructions Opera...

Страница 8: ...isconnect lubricants supply hose from Fill Port G 5 Plug Fill Port G and Overflow Port H Shutdown For normal system shut down disconnect power by turning off the ignition switch C NOTICE To prevent da...

Страница 9: ...X536 KIT reservoir 90 grease models 77X101 1 3a 100737 PLUG pipe 2 3b 108126 TEE pipe 1 3c 110996 NUT flanged hex 8 3d 111800 SCREW cap flange head 4 3e 115254 BREATHER 1 3f 194868 GASKET cover 1 3g 1...

Страница 10: ...awing 10 332540B Parts Drawing Model 77X100 Dyna Star Pump 60 Dip Stick Reservoir Vent Valve Model 77X101 Dyna Star Pump 90 Dip Stick Reservoir Vent Valve 1a 1b 4 3e 3d 3h 3f 3k 3c 3a 3g 3b 3j 3a 3d 3...

Страница 11: ...ts steel buna n rubber Reservoir overflow port size 1 2 inch npt Reservoir fill port size 1 2 inch npt Lubricant outlet port size 3 8 npt f Grease capacity Model 77X101 90 lb 41 kg Model 77X100 60 lb...

Страница 12: ...odels US inch Metric cm US inch Metric cm A 30 5 77 47 38 0 96 52 B 14 5 36 83 14 5 36 83 C 1 2 inch npt 1 2 inch npt D 1 2 inch 14 npt 1 2 inch 14 npt E 14 5 36 83 14 5 36 83 F 19 4 49 28 27 0 36 83...

Страница 13: ...Notes 332540B 13 Notes...

Страница 14: ...ser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of par...

Отзывы: