308353
11
Installation
(HYDRAULIC-POWERED PUMPS)
Fluid Line Accessories
Install the following accessories in the locations shown
in Fig. 3, using adapters as necessary:
A fluid filter (L)
with a 60 mesh (250 micron)
stainless steel element, to filter particles from the
fluid as it leaves the pump.
A fluid drain valve (M),
which is required in your
system, helps relieve fluid pressure in the hose
and gun (see the
WARNING
on page 10).
A gun (S)
dispenses the fluid. The gun shown in
Fig. 3 is an airless spray gun for light to medium
viscosity fluids.
A gun swivel (R)
allows freer gun movement.
A suction kit (T)
allows the pump to draw fluid
from a supply container.
KEY
A
Pump
B
Wall Bracket
C
Hydraulic Supply Line
D
Hydraulic Return Line
E
Drain Line (from pressure reducing valve)
F
Pressure Gauge
G
Flow Control Valve
H
Pressure Reducing Valve
J
Accumulator
K
Drain Line (from motor drip pan)
L
Fluid Filter
M
Fluid Drain Valve (required)
N
Electrically Conductive
Fluid Supply Hose
P
Fluid Whip Hose
R
Gun Swivel
S
Airless Spray Gun
T
Drum Suction Kit
U
Hydraulic Supply Line Shutoff Valve
V
Hydraulic Return Line Shutoff Valve
Y
Ground Wire (required, see page 7 for
installation instructions)
AA
Hydraulic Return Line Filter
04582B
Fig. 3
A
B
D
E
F
G
H
J
K
M
N
P
Y
200 LITER (55 GAL.)
DRUM
L
R
S
T
U
C
V
HYDRAULIC
POWER SUPPLY
DRAINAGE
CONTAINER
AA
TYPICAL HYDRAULIC-POWERED INSTALLATION