308152
41
Technical Data (Premier Pump)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m
#
/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Performance Charts: Premier Pumps
0
500
1000
1500
2000
2500
3000
3500
0
2
4
6
8
10
Fluid Outlet Pressure
13
26
39
psi
MPa, bar
cycles per minute
gpm
liters/minute
22.8
7.6
15.2
FLUID PRESSURE
24.5, 245
10.5, 105
A
B
C
0
50
100
150
200
250
300
0
2
4
6
8
10
Air Consumption
13
26
39
scfm
m
#
/min
cycles per minute
gpm
liters/minute
7.6
22.8
AIR CONSUMPTION
A
B
C
1.68
1.12
Test Fluid: No. 10 Weight Oil
3.5, 35
38.0
65
52
15.2
0.56
3.36
14, 140
7, 70
30.4
52
30.4
38.0
65
17.5, 175
2.24
21, 210
2.80