background image

Warnings

3A6932D

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 

exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. 

When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. 

Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this 

manual where applicable.

.

WARNING

FIRE AND EXPLOSION HAZARD

 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 

aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources, such as cigarettes and portable electric lamps.

• Ground all equipment in the work area.

• Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

• Use only grounded hoses.

Stop operation immediately 

if static sparking occurs or you feel a shock

.

 Do not use equipment 

until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 

may look like just a cut, but it is a serious injury that can result in amputation. 

Get immediate surgical 

treatment.

• Do not point dispensing device at anyone or at any part of the body.

• Do not put your hand over the fluid outlet.

• Do not stop or deflect leaks with your hand, body, glove, or rag.

• Follow the 

Pressure Relief Procedure

 when you stop dispensing and before cleaning, checking, or 

servicing equipment. 

• Tighten all fluid connections before operating the equipment.

• Check hoses and couplings daily. Replace worn or damaged parts immediately.

Содержание Compact Dyna-Star 25P686

Страница 1: ...classified locations Model 25P686 Auto Fill Shut Off 25P687 Auto Fill Shut Off with Follower Plate 12 and 20 liter 25U218 Auto Fill Shut Off with Follower Plate 60 lbs 3500 psi 24 1 MPa 241 3 bar Maxi...

Страница 2: ...n 5 Pressure Relief Procedure 5 Auto Fill Shut Off Installation 5 Follower Plate Installation Part 25P687 8 Auto Fill Shut Off Overview 11 Operation 12 Fill Refill the Tank 12 Troubleshooting 14 Techn...

Страница 3: ...ep work area free of debris including rags and spilled or open containers of solvent and gasoline Do not plug or unplug power cords or turn lights on or off when flammable fumes are present Use only g...

Страница 4: ...all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from tr...

Страница 5: ...1 Auto Fill Shut Off Installation 1 Disconnect power to the system FIG 2 2 Relieve pressure in the system following the Pressure Relief Procedure see page 5 This equipment stays pressurized until pre...

Страница 6: ...ct Dyna Star Auto Fill Shut Off plug Dispose of the plug according to local regulations FIG 4 and FIG 5 5 Grease the outside of the three 3 o rings on the Compact Dyna Star Auto Fill Shut Off cartridg...

Страница 7: ...em currently has a follower plate installation is complete For systems without a follower plate see Follower Plate Installation Part 25P687 page 8 9 Use two wrenches working in opposite directions on...

Страница 8: ...he tank and retain FIG 11 NOTE The lift ring for the 60 lbs tank is welded on to the can and is not removable 4 Lift the cover tank gasket and pump off of the tank and set aside 5 In a new installatio...

Страница 9: ...n to the tank FIG 13 8 Replace the nuts bolts and lifting ring NOTE The lift ring for the 60 lbs tank is welded onto the cover and is not removable 9 Tighten torque 10 12 ft lb 13 6 16 3 N m 10 Reconn...

Страница 10: ...Installation 10 3A6932D 11 Reconnect the power to the system FIG 15 FIG 14 FIG 15...

Страница 11: ...in the system Note The fill pump pressure can be as high as 2000 psi depending upon the lengths and diameters of Refilling line GG and Supply hose JJ Graco recommends using a 36 1 ratio or higher air...

Страница 12: ...the valve pin V1 which closes the inlet fluid path Pin V2 pops up once the tank is full When the fluid refilling path closes the refilling line GG pressurizes and brings the remote fill station pump...

Страница 13: ...here is a leak in the system NO 7 Turn off the remote fill station pump AA FIG 16 8 Pull and hold the fill valve pressure relief knob FF long enough to relieve line pressure between the fill valve EE...

Страница 14: ...n and has not been reset 1 Disconnect the refilling line 2 Pull and hold the fill valve pressure relief knob FF long enough to relieve line pressure between the fill valve EE and the Auto Fill Shut Of...

Страница 15: ...mum Working Pressure 3500 psi 24 1 MPa 241 3 bar Materials of Construction zinc plated steel parts buna N polyethylene PTFE fluoroelastomer WARNING This product can expose you to chemicals known to th...

Страница 16: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Отзывы: