Fluid
Fluid
Fluid Supply
Supply
Supply Line
Line
Line
1.
Use grounded, flexible fluid hoses (E). See
.
2.
If the inlet fluid pressure to the pump is more
than 25% of the outlet working pressure, the
ball check valves will not close fast enough,
resulting in inefficient pump operation. Excessive
inlet fluid pressure also will shorten diaphragm
life. Approximately 3–5 psi (0.02–0.03 MPa,
0.21–0.34 bar) should be adequate for most
materials.
3.
For maximum suction lift (wet and dry), see
. For best results, always
install the pump as close as possible to the
material source. Minimize suction requirements
to maximize pump performance.
Fluid
Fluid
Fluid Outlet
Outlet
Outlet Line
Line
Line
1.
Use grounded, flexible fluid hoses. See
,
2.
Install a fluid drain valve (F) near the fluid outlet.
3.
Install a shutoff valve (G) in the fluid outlet line.
12
334794F