background image

 

 Component Identification

SAFETY RELIEF VALVE:  This valve is designed to pre-
vent system failures by relieving pressure from the sys-
tem when the compressed air reaches a predetermined 
level.  The valve is preset by the manufacturer and 
must not be modified in any way.  To verify the valve is 
working properly, pull on the ring.  Air pressure should 
escape.  When the ring is released, it will reset.  

PILOT VALVE:  When the toggle is in the upright posi-
tion, all air from the air compressor is vented through 
the discharge muffler.  This gives an easy start feature.  
For normal operation, the toggle is in the 90° position.      

AIR INTAKE FILTER:  This filter is designed to clean air 
coming into the pump.  To ensure the pump continu-
ally receives a clean, cool, dry air supply this filter must 
always be clean and ventilation opening free from ob-
structions.  Replace filter element when necessary.

OIL FILL PORT/VENT:  Pour oil into the Oil Fill Port/Vent 
when required.

OIL SIGHT GLASS:  The Oil Sight Glass displays the oil 
level in the pump.  The oil level should be at the center 
of the Oil Sight Glass.  If low, add SAE 30W non-deter-
gent oil.

AIR COMPRESSOR PUMP (Single Stage):  To compress 
air, the pistons move up and down in the cylinders.  On 
the downstroke, air is drawn in through the air intake 
valves while the exhaust valves remain closed.  On the 
upstroke, air is compressed, the intake valves close 
and compressed air is forced out through the exhaust 
valves, into the discharge line, through the pilot valve 
and into the air tank.

AIR COMPRESSOR PUMP (Two Stage): A two stage 
compressor pump uses two different size cylinders with 
the intake valve of the second smaller cylinder linked 
to the exhaust valve of the first larger cylinder.  On the 
down stroke of the large cylinder, air is drawn through 
the intake valve while the exhaust valve remains closed. 
On the upstroke, air is compressed, the intake valve 
closes and compressed air is forced out through the ex-
haust valve, into the inter cooler and through the intake 
valve of the second smaller cylinder on its down stroke.  
On the upstroke of the smaller cylinder, the intake valve 
closes and the compressed air is compressed a second 
time and forced out the exhaust valve into the discharge 
line, through the tank check valve and into the air tank.

AIR TANK PRESSURE GAUGE:  The air tank pressure 
gauge indicates the reserve air pressure in the air tank (s).

PRESSURE REGULATOR:  The air pressure coming 
from the air tank is controlled by the regulator knob.  
Turn the pressure regulation knob clockwise to increase 
discharge pressure, and counterclockwise to decrease 
discharge pressure.

OUTLET PRESSURE GAUGE:  The outlet pressure 
gauge indicates the air pressure available at the outlet 
side of the regulator.  This pressure is controlled by 
the regulator and is always less or equal to the air tank 
pressure.

AIR TANK DRAIN VALVE:  The drain valve is used to 
remove moisture from the air tank(s) after the air com-
pressor is shut off.  

NEvER  attempt to open the drain 

valve when more than 10 PSI of air pressure is in the 
air tank! 

 To open the drain valve, turn the knob coun-

terclockwise.  

OIL FILL PORT

OIL SIGHT GLASS

Model 1310G

Model 1720G

Содержание AirMax 1310G

Страница 1: ...RTANT SAFETY INSTRUCTIONS Read all warnings and instructions in this manual SAVE THESE INSTRUCTIONS proven quality leading technology Model Horse Power and Motor Brand Maximum Working Pressure PSI MPa...

Страница 2: ...10 Operation Instructions 11 Start Up 11 Shutdown 11 Maintenance Instructions 12 Troubleshooting 13 Notes 15 THIS SPARK IGNITION SYSTEM COMPLIES WITH CANADIAN ICES 002 CE SYST ME D ALLUMAGE PAR TINCE...

Страница 3: ...tank immediately Never repair weld or make modifications to the air tank or its attachments Use only genuine repair parts for your air compressor Never make adjustments to the factory set pressures Se...

Страница 4: ...ng and combustion This will prevent the buildup of dangerous carbon monoxide gases Beware of poorly ventilated areas or areas with inadequate exhaust fans Sprayed materials such as paint paint solvent...

Страница 5: ...Do not alter or modify equipment Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfa...

Страница 6: ...l Fill Port 4 Air Compressor Pump 5 Pump Oil Drain 6 Oil Sight Glass 7 Pilot Valve 8 Engine Switch Item Description 9 Engine 10 Engine Throttle Control 11 Pressure Gauge Tank Psi 12 Tank Drain Valve 1...

Страница 7: ...3 Engine Air Throttle Control 4 Pilot Valve 5 Oil Sight Glass 6 Pump Oil Drain 7 Pressure Relief Valve 8 Pressure Gauge Tank Psi Item Description 9 Beltguard 10 Air Filter 11 Oil Fill Port 12 Pump 13...

Страница 8: ...t valve and into the air tank AIR COMPRESSOR PUMP Two Stage A two stage compressor pump uses two different size cylinders with the intake valve of the second smaller cylinder linked to the exhaust val...

Страница 9: ...10 Place air compressor at least 12 inches away from ob stacles that may prevent proper ventilation Do not place air compressor in an area Where there is evidence of oil or gas leaks Where flammable g...

Страница 10: ...ing the engine See engine manual Fill the fuel tank according to accompanying engine manual instructions Refer to the engine manual for all necessary mainte nance and adjustments Pre Start Checklist 1...

Страница 11: ...o the original position 4 Set pressure by adjusting the pressure regulator counterclockwise for less pressure and clockwise for more pressure Notice If you notice any unusual noise or vibration stop t...

Страница 12: ...whichever comes first The engine oil must be changed after the first 8 hours of operation and every 50 hours or 3 months whichever comes first Every 2 years an Authorized Service Technician should che...

Страница 13: ...o high enough pressure or defective Adjust Pressure Regulator to proper setting or replace Restricted air intake Clean or replace Air Intake Filter Air leaks or restrictions Check for leaks and repair...

Страница 14: ...vel with SAE 30W non detergent oil Wrong viscosity Drain oil Refill to proper level with SAE 30W non detergent oil Plugged oil dipstick vent Clean Plugged crankcase breather Clean or replace Oil leaks...

Страница 15: ...15 Notes...

Страница 16: ...16 Air Compressor Parts 262360 Model 1310G...

Страница 17: ...l Risk Of Burns 1 35 Engine 16E658 1 36 Decal Check Oil 2 37 Key 197792 1 Description Part Qty 38 Bolt 16E734 2 39 Sheave 16E678 1 40 Belt 16E682 1 41 Bushing 16E769 1 42 Edging Four Feet Required 16E...

Страница 18: ...18 Pump Assembly Parts 16E739 for use with Model 1310G...

Страница 19: ...use with Model 1310G DESCRIPTION PART QTY Kit Repair Valve Plate Assy 24E998 1 Includes 2 8 1 Kit Repair Piston Seals 24E999 2 Includes 15 Kit Repair Piston 24F002 2 Includes 11 14 Kit Repair Pump Ga...

Страница 20: ...20 Air Compressor Parts 262361 Model 1720G...

Страница 21: ...ing Five Feet Required 16E492 1 35 Locknut 111040 4 36 Washer 16E602 8 DESCRIPTION PART QTY 37 Edging Three Feet Required 16E492 1 38p Decal Warning Beltguard In Place 1 39 Beltguard Back 16E765 1 40p...

Страница 22: ...22 Pump Assembly Parts 16E738 for use with Model 1720G...

Страница 23: ...with Model 1720G DESCRIPTION PART QTY KIT REPAIR VALVE PLATE ASSY 24F003 1 INCLUDE 2 9 1 KIT REPAIR PISTON SEALS 24F004 1 INCLUDES 16 17 KIT REPAIR PISTON 24F006 1 INCLUDES 12 15 18 21 KIT REPAIR PUMP...

Страница 24: ...24 Notes...

Страница 25: ...30 W Non Detergent Pilot Valve Setting Cut out 125 PSI 175 PSI Cut in 95 PSI 145 PSI Air Tank Capacity 8 Gallons Performance CFM 40 PSI 16 8 19 7 CFM 100 PSI 13 1 18 3 CFM 175 PSI 17 5 Maximum Pressur...

Страница 26: ...grees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall...

Отзывы: