background image

310314

7

Component Identification and Function

Fig. 1

KEY

A

Pump

B

Ram (two used on 970056 and 970071,
one used on 970073)

C

Ram Plate

D

Electrically Conductive Air Supply Hose

   Main Air Bleed Valve (required, for pump

and ram)

F

Air Manifold

G

Pump Air Regulator

H

Pump Air Bleed Valve 
(required, for pump)

J

Air Line Filter

K

Bleed-Type Air Valve
(for accessories)

L

Pneumatic Crossover (for 970056 and
970071), Low–level Shutoff (970073)

N

Electrically Conductive Fluid Hose

S

Ball Valve

T

Ram Air Regulator

U

Ram Director Valve

V

Air Release Valve

W

Air Line Drain Valve

Y

Ground Wire (required; Refer to

      page 8 for setup)

AA

Safety Valve

CC

Bleed Handle

9224A

U

T

N

V

E

J

K

D

C

CC

B

A

AA

S

W

Y

H

G

F

Supply Unit A

Supply Unit B

Model 970056 Tandem Shown

L

A

B

Содержание 970056

Страница 1: ...41 Copyright 1999 Graco Inc is registered to I S EN ISO 9001 30 GALLON AND 55 GALLON 25 1 SENATOR Module Supply Units 2000 psi 138 bar Maximum Working Pressure 310314C Read warnings and instructions S...

Страница 2: ...rking Pressure Maximum Pump Air Input Pressure Parts Page 970056 Senatort Dura Flot 600 25 1 138 bar 13 8 MPa 2000 psi 6 2 bar 0 62 MPa 90 psi 15 970071 Senatort Dura Flot 600 25 1 172 bar 17 2 MPa 25...

Страница 3: ...re to the air powered ram D Never exceed the recommended working pressure or the maximum air inlet pressure stated on your pump or in the Technical Data on page 19 D Be sure that all spray dispensing...

Страница 4: ...ediately Do not repair high pressure couplings you must replace the entire hose D Fluid hoses must have spring guards on both ends to help protect them from rupture caused by kinks or bends near the c...

Страница 5: ...aising or lowering the ram D Before checking or servicing the ram or pump follow the Pressure Relief Procedure on page 11 TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or...

Страница 6: ...arts drawing D Main air bleed valve E is required in your system to shut off the air supply to the pump and ram Refer to the preceding WARNING When closed the valve bleeds off all air in the ram and p...

Страница 7: ...d Valve required for pump J Air Line Filter K Bleed Type Air Valve for accessories L Pneumatic Crossover for 970056 and 970071 Low level Shutoff 970073 N Electrically Conductive Fluid Hose S Ball Valv...

Страница 8: ...e using metal shims Secure base to floor using 13 mm 1 2 in anchors to prevent ram from tipping System Grounding WARNING FIRE AND EXPLOSION HAZARD Before operating the pump ground the system as explai...

Страница 9: ...am air motor via a 4 way piloted air valve 3 As the valve stops air to one ram it starts air to the other ram This allows constant material flow and changing out of material drums NOTE The position of...

Страница 10: ...it switch The switch shuts off the air to the ram NOTE The position of the air limit valve 2 on the ram determines when the ram air motor is turned on and off During operation this position can be adj...

Страница 11: ...terial contamination CAUTION Flush the system before performing the initial material loading procedure The system was fac tory tested using a light soluble oil a soybean oil or other oil as tagged Flu...

Страница 12: ...12 310314 Operation E C Fig 5 T U V CC G Model 970056 Tandem Ram Shown H 05698B DD 9219A...

Страница 13: ...the ram keep your fingers and hands away from the pump intake ram plate and lip of the drum CAUTION To help avoid damage to equipment do not use drums that have side bungs or large dents with this ram...

Страница 14: ...drum by operating air release valve 4 Raise wiper plate until it is completely out of drum 5 Remove empty drum 6 Inspect wiper plate and if necessary remove any remaining material or material build u...

Страница 15: ...ems 4 6 1 3 2 6 5 4 2 REF 922A Ref Part No No Description Qty Ref Part No No Description Qty 1 C59530 PUMP ram mounted 200 liter 55 gal See 308027 for parts 2 2 918468 KIT pneumatic crossover See 3102...

Страница 16: ...ms 4 6 1 3 2 6 5 4 2 REF 9303B Ref Part No No Description Qty Ref Part No No Description Qty 1 C59568 PUMP ram mounted 120 liter 30 gal See 308027 for parts 2 2 918468 KIT pneumatic crossover See 3102...

Страница 17: ...ose Includes Items 4 6 6 5 4 9302A Ref Part No No Description Qty Ref Part No No Description Qty 1 C59568 PUMP ram mounted 120 liter 30 gal See 308027 for parts 1 2 918478 KIT shut off low level pneum...

Страница 18: ...rance Dimensions A B C D E F G 14 2 mm 0 56 in Diameter Holes Model 970056 Ram Shown 9219A Model A Raised B Lowered C D E F G All 2578 mm 101 5 in 1575 mm 62 in 533 mm 21 in 635 mm 25 in 965 mm 38 in...

Страница 19: ...t Dura Flot 600 25 1 138 bar 13 8 MPa 2000 psi 5 5 bar 0 55 MPa 80 psi 970073 Senatort Dura Flot 600 25 1 138 bar 13 8 MPa 2000 psi 5 5 bar 0 55 MPa 80 psi Main air inlet for 970056 and 970071 3 4 in...

Страница 20: ...20 310314 Notes...

Страница 21: ...310314 21 Schematic Fig 6 Pneumatic Crossover Schematic Diagram Models 970056 and 970071 only...

Страница 22: ...shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other...

Отзывы: