Technical Data
3A1963G
7
Technical Data
.
* AC service coils are internally rectified and can be used in 50 or 60 Cycle (Hz) lines.
NOTE:
AC voltage service with transient surges over 1000 volts may require a varistor to be placed in parallel with
the coil.
NOTE:
Normally open versions of the vent valve are not recommended for use with oil and a pump that outputs less
than 1.5 cu. in./min.
DIRECT MOUNT VENT VALVE FOR G3 PUMPS
US
Metric
Maximum working pressure
3500 psi
24 MPa, 241 bar
Pressure Relief Valve
Factory Set Pressure
4000 psi + 10%
27.6 MPa, 275.8 bar + 10%
Reset Pressure
80% of pressure
Relief Rate
0.13 gallons/sec @3000 psi
0.57 liters/sec @21 MPa. 207 bar
Solenoid Valve
Flow
Up to 5 gpm (18.9 lpm)
Materials of Construction
Wetted materials on all models
zinc plated steel, carbon steel, 6061 T6 aluminum, fluoroelastomer,
polyurethane
Weight
37.72 oz.
1069.5 grams
Solenoid Coil
Resistance (DC) @ 68°F (20°C )
(Ohms)
Initial Current Draw (Amps)
12 Volt DC
7.2
1.67
24 Volt DC
28.8
0.83
115 AC*
568
0.17
230 AC*
2304
0.09