![Graco 562870 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/graco/562870/562870_instructions-manual_2251709018.webp)
Step-By-Step Programming Instructions
18
313903B
•
Stop Bits:
Choose one: 1 or 2 bits.
a. Press the
SLCT
button to toggle between
choices.
b. When choice displays, press the
PGRM
but-
ton to advance to the next programming
option.
•
Parity:
Choose one: ODD, EVEN and SELECT.
a. Press the
SLCT
button to toggle between
choices.
b. When choice displays, press the
PGRM
but-
ton to advance to the next programming
option. Since there are no additional options,
the display returns to the start of the Serial
Port selection.
2.
Push the
SLCT
button to toggle to the Global Set-
tings.
Global Settings
1.
Press
PRGM
button to enter the options for Global
Settings.
•
Faults to Skip (nuisance faults):
Allows Senti-
nel II to ignore nuisance faults. It will delay log-
ging a fault until one, two or three consecutive
faults are received.
Choose either 1, 2 or 3:
a. Press the
SLCT
button to toggle between
choices.
✓
1: The normal operation setting uses 1.
Faults on the first occurrence of a time out.
✓
2 or 3: If 2 or 3 is selected a + (plus) sign
will display in the monitor window to indicate
that alarm times are being dynamically
adjusted.
NOTE: The + (plus) sign also appears if the
Tachometer option is chosen, page 16.
b. When choice displays, press the
PGRM
but-
ton to advance to the next programming
option.
•
Invert Relays (fault relay logic): Allows selection
of whether the zone fault relays and the TTL
output will energize or deenergize when a fault
is registered.
Choose either YES or NO:
a. Press the
SLCT
button to toggle between
choices.
✓
NO: The fault relay contacts will be deener-
gized during normal system operation and
energize upon a fault.
✓
YES: The fault relay contacts will be ener-
gized during normal system operation and
deenergize upon a fault.
b. When choice displays, press the
PGRM
but-
ton to advance to the next programming
option. Since there are no additional options,
the display returns to the start of the Global
Settings selection.
2.
Push the
SLCT
button returns to the CONFIGURA-
TION?ZONE1 option.
Exit/Save Changes
1.
Press
RST/CLR
button at any time moves to the exit
routine.
2.
You will be prompted to Save Changes. The default
response is NO.
3.
If all modifications to the Sentinel II are satisfactory
and ready to be permanent, press the
SLCT
button
to change the response to YES.
AUTOMATIC SYSTEM ACTIVATION HAZARD
Unexpected activation of the system could result in seri-
ous injury, including skin injection and amputation.
This device has an automatic timer that activates the
pump lubrication system when power is connected or
when exiting the programming function. Before you
install or remove the Lube Sentinel II Monitor from the
system, disconnect and isolate all power supplies and
relieve all pressure.