Instructions

Gateway Network 
Communication 
Assembly

Used to control, monitor, and download production data from various Graco System 
Controllers to a PLC or PC for automation or production information reporting. For 
professional use only.

Not approved for use in explosive atmospheres or hazardous (classified) locations. 

See pages 3 and 4 for information and model numbers 
for each Gateway Assembly.

Important Safety Instructions

Read all warnings and instructions in this 
manual and in your proportioning system 
manual before using the equipment.

 

Save all instructions. 

Содержание 3A7639A

Страница 1: ...production information reporting For professional use only Not approved for use in explosive atmospheres or hazardous classified locations See pages 3 and 4 for information and model numbers for each...

Страница 2: ...Conversion Module 16K465 28 25B489 Gateway Ethernet Assembly with Ethernet Switch 15V342 30 Appendix A DeviceNet Secondary Communication 32 Overview 32 Introduction 32 DeviceNet Port Protocols 32 Abou...

Страница 3: ...raco system It is the responsibility of the integrator or user to ensure proper configuration of the communication hard ware on the PLC side NOTE The Red Lion Gateway Module Graco part no 18C235 used...

Страница 4: ...e through a fiber cable in hazardous and non hazardous locations NOTE This communication method is used for the ADCM and DCM modules regardless of where they are placed Model 25B489 Gateway Ethernet A...

Страница 5: ...s potential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gaso...

Страница 6: ...worn or damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards...

Страница 7: ...or the operator and so equipment is easily accessi ble for maintenance 4 Drill mounting holes in the wall Install anchors as needed 5 Bolt equipment securely This equipment is not for use in explosive...

Страница 8: ...ateway Module 5 Connect a communications wire cable protocol dependent from the Gateway Module to the PLC See Communication Connections page 11 NOTE Graco provides expansion cards for DeviceNet and Pr...

Страница 9: ...osure 1 NOTE The strain relief fitting or connector must be provided in the field according to local electrical codes 5 Connect the supply ground wire to the ground terminal block 9 in the enclosure 1...

Страница 10: ...Install the Gateway Assembly Hardware 10 3A7639A FIG 4 Power Connections 14 13 10 Model 25B471 Models 25B472 and 25B473 Model 25B486 Model 25B489 10 13 14 14 10 14 10...

Страница 11: ...air cable with shield wire See Electrical Sche matics on page 16 for pin connections Communication Wire Cable to PLC This connection is protocol dependent USB Port Models 25B471 2 3 come with 50 ft of...

Страница 12: ...FIG 6 Gateway DeviceNet and Profibus Assembly Cable Connection Points Models 25B472 and 25B473 Optional fiber optic cable for connection to an ADCM or DCM module Cable options are 17T898 3 m 16M172 15...

Страница 13: ...EtherNet Switch for EtherNet conversion to the PC PLC USB Port Ethernet network cable FIG 8 Gateway Ethernet Assembly w Ethernet Switch Cable Connection Points Model 25B489 Install the Gateway Assembl...

Страница 14: ...x COMM COMM Tx RTS PIN 1 PIN 6 USB GREEN AMBER LED YELLOW LED ETHERNET NIC USB PG 1 COMMON 2 24 VDC 10 3 N C POWER CONNECTOR ti38199a FIG 9 Gateway Module Port Pin Outs RS485 TxB TxA RxA RxB TxEN COMM...

Страница 15: ...dware 3A7639A 15 FIG 11 Programming Port Options FIG 12 Ethernet Connection GREEN AMBER LED YELLOW LED ETHERNET USB PG A USB PG port cable is provided with all models for configura tion and setup GREE...

Страница 16: ...45 PORT 15V344 TERMINAL ADAPTER 8 7 6 5 4 3 2 1 PORT A RS232 PGM PORT B RS485 PORT C RS232 USB HOST ETHERNET USB DEVICE 18C235 GATEWAY MODULE GND AC POWER INPUT REFERENCE ONLY 065145 BLUE 1 547005 BLU...

Страница 17: ...TE B DRAIN SH EXTERNAL CONTROLLER RS485 2 WIRE 15V339 ENCLOSURE 121700 CABLE GND DEVICENET 18C236 PROFIBUS 18C237 18C236 DEVICENET OR 18C237 PROFIBUS ADD ON COMM MODULE EXT CONTROL NETWORK CABLE REFER...

Страница 18: ...he cover 2 Install the SD card in the orientation shown in FIG 17 3 Install the Gateway Assembly cover and connect power FIG 16 Electrical Schematic Model 25B489 N L V V V V 112443 GND TERM BLOCK 19Y9...

Страница 19: ...sup ported protocols System Requirements Crimson 3 1 is designed to run on any version of Micro soft Windows from Windows Vista onward Memory requirements are modes and any system that meets the mini...

Страница 20: ...f a later version than the one you are using is found Crimson will ask if it should download the upgrade and update your software automatically You may also manually download the upgrade from Red Lion...

Страница 21: ...ce does not contain an older version of the current database After this first download Crimson uses a process known as incremental download to ensure that only changes to the database are transferred...

Страница 22: ...t device This setting is stored in the database and can be configured on a perfile basis Enabling database upload will slow the download process somewhat and may fail with extremely large databases co...

Страница 23: ...updated driver Follow the instructions on the screen to automatically find and select the drivers 1 Go to Start Programs Graco Red Lion Crimson 3 0 3 1 and run the program The Red Lion Crimson 3 0 3...

Страница 24: ...Parts 24 3A7639A Parts 25B471 Gateway Ethernet Assembly 6 8 7 18 10 16 3 1 2 20 4 5 9 13 14 19 8 24 25 35 30 26 28 23 underside of enclosure...

Страница 25: ...4 8 120838 End block din rail 2 9 112443 Terminal block ground 1 10 19Y920 Power supply 1 13 15V344 Connection converter terminal block to RJ45 1 14 18C235 Gateway Assembly 1 16 15V345 Grommet cable...

Страница 26: ...Parts 26 3A7639A 25B472 Gateway DeviceNet Assembly 25B473 Gateway Profibus Assembly 6 8 7 18 10 16 3 1 2 20 4 5 9 13 14 19 8 24 25 15 15 9 29 30 31 35 30 26 28 23 underside of enclosure...

Страница 27: ...ail 2 9 112443 Terminal block ground 1 10 19Y920 Power supply 1 13 15V344 Connection converter terminal block to RJ45 1 14 18C235 Gateway Assembly 1 15 Card expansion 18C236 DeviceNet 25B472 only 1 18...

Страница 28: ...Parts 28 3A7639A 25B486 Gateway Ethernet Assembly with Fiber Conversion Module 16K465 6 8 7 18 10 16 3 1 2 20 4 5 9 14 19 8 11 32 35 30 26 28 26 28 23 underside of enclosure...

Страница 29: ...rail 1 7 103833 Screw machine CRBH 4 8 120838 End block din rail 2 9 112443 Terminal block ground 1 10 19Y920 Power supply 1 11 16K465 Converter serial to fiber optic 1 14 18C235 Gateway Assembly 1 1...

Страница 30: ...Parts 30 3A7639A 25B489 Gateway Ethernet Assembly with Ethernet Switch 15V342 6 8 7 18 10 16 3 1 2 20 4 9 14 19 8 12 5 9 24 35 30 30 26 26 28 28 23 underside of enclosure...

Страница 31: ...Din rail 1 7 103833 Screw machine CRBH 4 8 120838 End block din rail 2 9 112443 Terminal block ground 2 10 19Y920 Power supply 1 12 15V342 Switch ethernet 1 14 18C235 Gateway Assembly 1 16 15V345 Gro...

Страница 32: ...Option Card Pin Outs V Position 1 of the pluggable connector provides a CAN ground connection This terminal is isolated from the Gateway Assembly CAN_L Position 2 of the pluggable connector provides t...

Страница 33: ...Appendix A DeviceNet Secondary Communication 3A7639A 33 FIG 21 DeviceNet Port Pin Outs and PLC Connection V LED CAN_L DRAIN CAN_H V TI13963a DeviceNet Option Card PLC Connection...

Страница 34: ...number of con nections that facilitate data transfer between a Priority and Secondary devices The following sections detail the connection types supported by the Gateway Assem bly I O Bit Strobe Conne...

Страница 35: ...oduction Profibus DP stands for Profibus for Decentralized Peripherals Profibus DP is a device level bus that sup ports both analog and discrete signals It has wide spread usage for such items as remo...

Страница 36: ...can be defined in bytes words or double words Since start addresses between the Priority and the Secondary can be different one could give its start address and length in bytes and the other in words...

Страница 37: ...Appendix B Profibus DP Secondary Communication 3A7639A 37...

Страница 38: ...Dimensions 38 3A7639A Dimensions California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Страница 39: ...llector VOH 15 Vdc VOL 0 5 V 25 mA maximum Ethernet Port 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card Memory On board user memory 4 Mbytes of non volatile Flash memory On b...

Страница 40: ...terial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIE...