Component Identification
18
309028ZAT
General Description
A general description of the Uni-Drum Supply System
helps the installers and operators become familiar with
the system components. Contact your Graco distributor
for help in choosing accessories to suit your particular
needs.
Before you install the system, you should be familiar
with the parts described in the following paragraphs.
System Components
See F
•
Uni-Drum Supply Unit (A,B)
is usually setup to
alternate the material supply operation between the
left hand (LH) and right hand (RH) Supply Units,
which is accomplished using a combination of
robotic software programming (provided by others)
and manual operators. Drum changeovers occur
after the Follower Plate (D) has reached its preset
low limit level in the drum. Alternating between
Supply Units eliminates the downtime that is usually
expended unloading an empty drum and reloading a
full drum.
-
LH Supply Unit (A) accommodates one 300
gallon (1200 liter) drum. The LH Supply Unit
has a local Pneumatic Logic Panel (G) and
Junction Box Panel (H).
-
RH Supply Unit (B) accommodates one 300
gallon (1200 liter) drum. The RH Supply Unit
has a local Pneumatic Logic Panel (G) and
Junction Box Panel (H).
•
The two
Dura-Flo™ 1800 Pumps (C)
have XL
10000™ air motors. The Pumps evacuate material
from the drum.
•
The Follower Plate (D)
is connected to the ram
assembly and is designed to apply an even amount
of pressure to the material in the drum. With the
Follower Plate in its raised position, the operator
moves a drum inside the frame. The Follower Plate
is lowered directly on top of the material in the drum.
When pressure is applied to the Follower Plate, the
material is pumped out of the drum through hoses,
which are attached to the Pump outlet ports. When
the drum is empty, the operator raises the Follower
Plate, removes the empty drum. The process is
repeated when another drum is ready to be
unloaded.
•
Pneumatic Panel Air Filter (F)
filters air to the
Pneumatic Logic Panel (G). The 5 micron filter
removes particles, such as dust, moisture, foreign
matter and other contaminants from the
compressed air.
•
The
Safety Pins (M)
are used to keep the ram from
lowering while in the fully raised position during
drum changes or maintenance of the supply
system.
•
Main Air Shutoff Valve (P)
is used to open or
shutoff the air supply to the entire Supply Unit (A,B).
Pneumatic Logic Panel (G)
See F
The Pneumatic Logic Panel (G) includes the following
system components. For more information, refer to the
on page 92.
•
PUMP NO. 1 REGULATOR Control Knob (AC)
controls Pump speed and outlet pressure for Pump
No. 1 by adjusting the air pressure to the Pump.
•
PUMP NO. 1 PRESSURE Air Gauge (AA) displays
the amount of air pressure supplied to Pump No. 1.
•
PUMP NO. 2 REGULATOR Control Knob (AE)
controls Pump speed and outlet pressure for Pump
No. 2 by adjusting the air pressure to the Pump.
•
PUMP NO. 2 PRESSURE Air Gauge (AB) displays
the amount of air pressure supplied to Pump No. 2.
•
FOLLOWER VENT Directional Valve (AD) is
activated to open the vent to relieve container
pressure.
•
RAM UP Pushbutton (AF) turns on air pressure to
raise the Follower Plate (D) when used in
conjunction with the RAM POSITION Switch (AG).
•
The RAM POSITION Switch (AG) performs the
following three functions:
-
Place the switch in the RAISE position to raise
the Follower Plate (D).
-
Place the switch in the HOLD/NEUTRAL
position to hold the Follower Plate (D) in the
current position.
-
Place the switch in the LOWER position to
lower the Follower Plate (D).
Содержание 309028ZAT
Страница 14: ...Component Identification 14 309028ZAT FIG 5 Pneumatic Logic Panel Interior AJ AK AL ...
Страница 41: ...Junction Box Panel Service 309028ZAT 41 FIG 20 T10196 Pressure Switch Solenoid Valve ...
Страница 75: ...Parts 309028ZAT 75 Follower Plate Assembly 241891 and 243510 FIG 32 ...
Страница 77: ...Parts 309028ZAT 77 PLC Pneumatic Logic Panel FIG 33 915 909 905 915 910 917 906 ...
Страница 78: ...Parts 78 309028ZAT FIG 34 945a 955 939a 912b 912a 914a 954a 909a 953a 901b 902b ...
Страница 80: ...Parts 80 309028ZAT PLC Interface Accessory Kit 241838 and 24V775 FIG 35 ...
Страница 82: ...Parts 82 309028ZAT Junction Box Panel 195320 and 119773 FIG 36 ...
Страница 84: ...Parts 84 309028ZAT Follower Plate 233041 FIG 37 413c 413b 413a DETAIL A DETAIL B SEE DETAIL B SEE DETAIL A ...
Страница 88: ...Parts 88 309028ZAT Elevator Assembly 241902 FIG 39 Ref Ref Ref ...
Страница 93: ...Pneumatic Diagram 309028ZAT 93 ...