308950
Troubleshooting
Description
Problem
Solution
Timer fails to activate sole-
noid
No power supplied to solenoid
Solenoid faulty
Timer faulty
Low Level alarm
Power light off: timer is not receiving power.
Verify connections and verify power supply
Power light on: verify solenoid connections
Replace solenoid
Replace timer
Refill reservoir
Pressure switch fails to shut
down system
Pressure switch incorrectly wired
Pressure switch faulty
Timer faulty
Verify proper connections
Replace pressure switch
Replace timer
Accessories and Kits
Repair Kit 241574
Repair Kit 241574 is available. It contains two junction
box connectors and six rubber grommets, as shown.
8856A
24V Air Solenoid 114488
9008A
3/8” npt (3)
Manual
Activation
Button
Pressure Switch 115124
1/4” npt(f)
9146A