7
308950
Setup
WARNING
AUTOMATIC SYSTEM ACTIVATION
Do not connect power to timer if the pump power supply is on, unless activation of the automatic
lubrication system is intended. This device is an automatic timing device that activates the output
circuit (air solenoid valve) upon power connection or upon exit of the programming function.
Ignoring this warning could lead to serious injury including fluid injection and amputation due to
activation of connected system components.
System Set-Up Menu
The System Set-Up Menu is used to configure the type of pump and automatic lubricating system that is connected
to the Lubrication Controller. The modes in the System Set-Up Menu progress in the order shown in the table
below.
To access the System Set-Up Menu, press the UP and DOWN buttons simultaneously, and hold them down for two
seconds.
Parameter
Description
Screen Display
Operation
Lubrication system
Pressure-switch-controlled
on single-line systems
Press the UP button to toggle between
h
i
y
type
No pressure-switch-control,
just timer
gg
the two options.
Press the TIME button to accept the change. Press the RESET button to cancel the change.
Time Menu
The Time Menu is used to adjust the
Pump On cycle and Pause Interval. The modes in the Time Menu progress in
the order shown in the table below.
To access the Time Menu, press and hold the TIME button for two seconds.
Parameter
Description
Screen Display
Operation
Pump On time
Indicates the minimum
Pump On time in
minutes : seconds
Maximum: 59:50
Minimum: 00:10
Press the UP and DOWN buttons to
adjust the setting.
Press and hold the TIME button for two seconds to advance to the next option.
Pause interval
Indicates the
Pause
Interval between lubrication
cycles in hours : minutes
Maximum: 99:59
Minimum: 00:01
Press the UP and DOWN buttons to
adjust the setting.
Press and hold the TIME button for two seconds to return to normal operating mode.