Installation
3A8503C
13
2. Remove the ground screws (green) from the
grounding standoffs.
3. Use ground screws to install the ground ring
terminal onto the ground standoffs for each cable.
4. Slide the strain relief (ZA, ZB) into the TPC
enclosure slots (ZS).
5. Plug in the connectors (J1A, J2A, J1B, J2B) and
tighten connector screws.
NOTE:
The A-side connectors (J1A, J2A) are on the
left. The B-side connectors (J1B, J2B) are on the
right.
6. Reinstall the TPC cover (ZC).
Connect the CAN Cable to the TPC
NOTE:
The CAN cable allows the TPC to communicate
with the Reactor and provides low voltage power to the
TPC. It does not provide power to run the electric
motor.
1. Connect the CAN cable to the TPC.
2. Connect the other end of the CAN cable to the
open CAN communication connection on the
electric motor control module (MCM). See the
Component Identification section in your Reactor 3
operation manual.
Connect Power to the TPC
TPC Power
100-120 Vac, 8 A, 50/60 Hz
200-240 Vac, 4A, 50/60 Hz
NOTE:
Certain GFCI outlets have been known to trip
while using this product. GFCI outlets have a range of
sensitivities. Electric motor controllers can cause false
trips of GFCI outlets.
Utilize the included field wireable IEC320 C13 plug, or a
cable with a C13 plug to provide power to the TPC.
When installed in a truck or trailer, ground the TPC to
the frame of the truck or trailer.
CAN Cable
Ground Screw
Ground Screw
Part
Description
121055 CORD, SET, US MX, PR, CA, TW. 115V, 10A
121054 CORD, SET, US, 250V, 10A, 10 FT
121056 CORD, SET, FR, GER, IS, NL, NO, TR, 250V
121057 CORD, SET, UK, IE, MY, SG, 250V, 10A
121058 CORD, SET, ISRAEL, 250V, 10A
124864 CORD, SET, ADPTR, AUSTRALIA, 8 FT
124861 CORD, SET, ADPTR, ITALY, 8 FT
124863 CORD, SET, ADPTR, SWITZERLAND, 8 FT
124862 CORD, SET, ADPTR, DENMARK, 8 FT
121060 CORD, SET, S AFRICA, INDIA, 250V, 16A
Содержание 26D000
Страница 34: ...Dimensions 34 3A8503C...