background image

Installation

3A5656A

5

12. Add the green ground wire that you disconnected 

from the old HMI to the new connector on the left.

13. Connect the RS-485 (COM) ribbon cable included in 

the kit and the newly connected power cable to the 
replacement HMI as shown in Figure 6. 

14. Using the double sided tape, fasten the spacer 

angles to the inside of the panel. See Figure 7.

NOTE:

 Two spacer angles fit in the left and right side of 

the opening and two fit in the top and bottom. The small 
ridges should be placed over the edges of the opening 
and the tape should be placed along the longer, flat part 
of the spacer angles. Press the spacer angles tightly 
against the inside of the front panel to secure them.

15. Feed the power cable and ribbon cable through the 

opening in the front panel.

16. Place the HMI into the panel and fasten it with the 

four retaining clips that are included in the kit. 
Tighten the screws in the retaining clips until the 
HMI is secure.

NOTE: 

You may need to back the screws in the retain-

ing clips almost all the way out to attach the clips before 
tightening them.

F

IG

. 7: Attach the HMI to the Front Panel

HMI

(Not included in kit. For Installation Reference Only.)

Two-sided

Two Sets of

Retaining Clips

Tape

Spacer Angles

Front Panel

Содержание 26C194

Страница 1: ...Human Machine Interface HMI display on the control boxes of PD44 systems For professional use only Part No 26C194 Important Safety Instructions Read all warnings and instructions in this manual and in...

Страница 2: ...4 control boxes Important features of this replacement kit include The new HMI is slightly different in size than the pre vious version so spacer angles are included in the kit to allow for proper mou...

Страница 3: ...electric box See Figure 2 5 Remove the cover 6 Loosen the fastener a quarter turn and lift the hinged portion of the control box as shown in Figure 3 PRESSURIZED FLUID HAZARD The equipment in this sys...

Страница 4: ...nnection with the blue and white wires The green ground wire 9 Loosen and remove the four HMI retaining clips and push the HMI out through the front panel of the con trol box 10 Unscrew the DC wires f...

Страница 5: ...e opening and the tape should be placed along the longer flat part of the spacer angles Press the spacer angles tightly against the inside of the front panel to secure them 15 Feed the power cable and...

Страница 6: ...tery from the PLC See Figure 8 for the location of the battery 2 Place the new EEPROM in the battery slot 3 Plug in the power cord and turn on the power to the control box The program loads 1 2 second...

Страница 7: ...G 9 HMI Replacement Kit Parts 1 5 2 x4 4 x2 3 x2 Ref Part Description Quantity 1 CABLE adapter hmi replacement 1 2 TAPE foam 1 2 wide 4 3 SPACER hmi 5 inch 2 4 SPACER hmi 7 inch 2 5 17J400 DISPLAY hmi...

Страница 8: ...X 1441 MINNEAPOLIS MN 55440 1441 USA Copyright 2016 Graco Inc All Graco manufacturing locations are registered to ISO 9001 www graco com Revision A March 2018 Graco Information Sealant and Adhesive Di...