background image

Warnings

3A5453D

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. 
When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. 
Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this 
manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in 

work area

 can ignite or explode. Paint or 

solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion:

Do not use or clean with materials having flash points lower than 140° F (60° C). Use only 
non-flammable or water-based materials. For complete information about your material, request 
the Safety Data Sheets (SDSs) from the material distributor or retailer.

Use equipment only in well-ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic 
drop cloths (potential static sparking). 

Ground all equipment in the work area. See 

Grounding 

instructions.

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Use only grounded hoses.

Stop operation immediately 

if static sparking occurs or you feel a shock

.

 Do not use equipment 

until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

EQUIPMENT MISUSE HAZARD

 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Specifications

 in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 
retailer.

Do not leave the work area while equipment is energized or under pressure. 

Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 
manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and 
create safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Содержание 26C150

Страница 1: ...gh Viscosity up to 2000 centipoise Model 26C818 Low Viscosity up to 1000 centipoise 100 psi 0 7 MPa 7 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual before using the equipment Save these instructions WARNING FIRE AND EXPLOSION HAZARD Use only non flammable or water based materials with this equipment Do not use materials having flash po...

Страница 2: ...tor 6 Operation 8 Pressure Relief Procedure 8 Operate the Agitator 8 Check Fluid Viscosity 8 Maintenance 9 Lubricate the Air Motor 9 Repair 9 Flush the Air Motor 9 Service 10 Parts 12 Accessories 13 Dimensions 14 Technical Specifications 15 California Proposition 65 15 Graco Standard Warranty 16 Graco Information 16 ...

Страница 3: ...oses Stop operation immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or temperature rati...

Страница 4: ... fluid connections before operating the equipment Check hoses tubes and couplings daily Replace worn or damaged parts immediately TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheets SDSs to know the specific hazards of the fluids you are using Store hazardous fluid in approved containers...

Страница 5: ...t Air regulator and gauge C to control air motor and agitator speed Air line lubricator D downstream from the filter install an air line lubricator for automatic air motor lubrication Set the lubricator feed rate at 1 drop of oil per minute for high speed or continuous duty usage Do not overfeed oil or exhaust air may become contaminated To manually lubricate the air motor see Lubricate the Air Mo...

Страница 6: ...pter into the drum This motion will cause the blades to spin outward If the resistance does not change verify that the shaft is not contacting the base of the container 3 Position the air motor so the air line can be attached easily to the needle valve 1 8 npt inlet without obstructing any other system components 4 Attach an air line quick disconnect valve or ball valve for main air shutoff Order ...

Страница 7: ... the bung until it bottoms out then back it out until the widest portion on of the adapter top is pointing just to the left of the center of the drum Fig 4 3 Turn down the locking ring until it contacts the drum Use an appropriately sized pipe wrench or adjustable wrench to tighten the adapter down until the widest portion of the adapter top is in line with the drum NOTE The locking ring 16H295 an...

Страница 8: ...agitator the same agitator speed will be set each time the agitator is used 5 Operate the agitator continuously while supplying paints or other fluids to the system 6 To stop the agitator close the master air valve A or close the agitator needle valve 11 Check Fluid Viscosity If the agitator is in a closed drum remove the agitator to check fluid viscosity or siphon some fluid from the 3 4 npt drum...

Страница 9: ...ilated area 1 Follow the Pressure Relief Procedure page 8 2 Add several teaspoons of solvent or spray the solvent directly into the motor 3 Rotate the shaft by hand in both directions for a few minutes 4 Reconnect the air line and slowly apply pressure until there is no trace of solvent in the exhaust air 5 Lubricate the motor with a squirt of lightweight oil in the chamber NOTICE Not lubricating ...

Страница 10: ...ean with a compatible solvent and inspect the shaft 2 and blades 6 7 for wear or damage 2 If parts need replacing follow steps 1 4 under Air Motor to remove the air motor 3 Use the 1 8 hex to remove the other two setscrews 8 on the coupler 4 Slide the shaft off 2 5 If needed use a 3 mm 1 8 in hex to remove the setscrew 8 on the hub assembly 6 or 7 Slide the hub blade assembly off of the shaft 6 To...

Страница 11: ...Repair 3A5453D 11 ...

Страница 12: ...Parts 12 3A5453D Parts WL D Torque to 65 in lb 7 3 N m 1 Torque to 80 in lb 9 N m 2 ...

Страница 13: ...cluded with Items 3 6 and 7 7 9 101679 SETSCREW 3 8 24 sst included with Item 4 3 11 206264 VALVE needle 1 12 169969 FITTING air line 1 13 113779 MUFFLER 1 15 116343 GROUND SCREW 1 16 113082 O RING 1 19 17E503 TAG safety agitator not shown 1 Air Motor Repair Kits may be purchased separately Order part 224954 for Model 26C150 high viscosity or part 207335 for Model 26C818 low viscosity Available in...

Страница 14: ...818 low viscosity A 5 1 in 130 mm 4 2 in 107 mm C Minimum 33 in 838 mm 33 in 838 mm D Maximum 35 1 in 891 mm 35 1 in 891 mm Dimension Model 26C150 high viscosity Model 26C818 low viscosity B 5 6 in 142 mm 4 7 in 119 mm E Minimum 32 5 in 826 mm 32 5 in 826 mm F Maximum 34 6 in 879 mm 34 6 in 879 mm E ti32033b WL D D C E F ...

Страница 15: ...Pa 7 bar Sound pressure measured 3 28 feet 1 meter from equipment Sound power measured per ISO 9614 2 Air Driven Expanding Blade Mixer Model 26C150 High Viscosity US Metric Maximum working pressure 100 psi 0 7 MPa 7 bar Maximum recommended agitator speed 500 rpm Air consumption at 400 rpm with 100 psi 0 7 MPa 7 bar air inlet pressure 22 scfm 0 62 m3 min Weight 13 3 lb 6 0 kg Bung adapter thread si...

Страница 16: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warr...