Installation
6
311307E
12 VDC model 260112
Motor current rating: 62 amps full load. Use 8
AWG or larger for supply wires.
1. Turn power switch OFF.
2. Use an appropriate size ring terminal to
attach the black (negative) supply wire to
the negative post near the back of the
motor. Ensure the existing small black wire
remains on the post.
3. Use an appropriate size ring terminal to
connect the red (positive) supply wire to the
relay post (16) at the front of the motor.
This post is the one closest to the pump
inlet and outlet. Do not connect the positive
supply wire directly to the positive post of
the motor or the motor will run continuously.
Ensure the small red wire remains on the
front post.
Priming
1. Attach the connection hose to the outlet of
the pump. Insert the opposite end of the
hose into the tank through the fill opening.
2. Turn power switch ON. The pump should
prime in a few seconds. If priming does not
start, see steps 4-6.
3. When pumps starts to prime, turn power
switch OFF. Go to step 7.
4. If priming does not start, remove the outlet
fitting (18) by disconnecting the small diam-
eter sensing hose (17) from the outlet fitting
and remove the fitting.
5. Fill the outlet port of the pump to within 1/2
in. (13 mm) of the top.
6. Replace the outlet fitting and reconnect the
sensing hose. Repeat step 2. Once the
pump is primed the inlet check valve will
prevent loss of prime.
7. Attach the connection hose to the system
plumbing.