Installation
3A8109A
9
Motor Electrical Connections
NOTE:
Over-current protection is provided, for both AC
and DC models, within the enclosure (1).
The AC and DC models both have pre-wired controllers.
The power sources and connections differ as follows:
•
For AC models (25T651)
, simply plug the power
cord (18) into a standard 115 VAC receptacle. See
F
•
For DC models (25T650)
, connect red wire on the
controller (15) to the red wire on the power supply
(13), and the black wire on the pump (2) to the black
wire of the power supply (13).
To reduce the risk of electrical shock;
•
All electrical wiring must be done by a qualified
electrician and comply with all local codes and reg-
ulations.
•
Install the pump with a dedicated means to discon-
nect the main power to the pump.
NOTICE
To avoid potential damage to equipment, verify that all
system valves are open before connecting power to
the pumps.
F
IG
. 4 AC Power Source
18