Setup
8
3A5202A
Water Connections
1.
Close the water accessory shut-off ball valve (U).
2.
Ensure the water supply pressure is between 30-70
psi. The water pressure regulator (W) has been pre-
set to 30 psi and does not usually require adjust-
ment.
NOTE: The water pressure regulator (W) reduces
the supply pressure to a constant value so that the
water metering valve (Y) does not need to be
adjusted due to fluctuations in supply pressure. The
water pressure regulator (W) must be set below the
minimum pressure expected from the water sup-
ply(s) used, and if necessary can be set down to 20
psi (1.3 bar, 0.13 MPa).
3.
Connect water supply hose (WH) to water supply
inlet (V).
4.
Turn on water supply.
Electrical Components
1.
Plug the power cord (PC) to the electrical box (EB).
2.
Plug the power cord into a standard NEMA 5-15
wall outlet.
NOTE: Use a 3-prong NEMA 5-15 power cord.
Grounding
The system is grounded through the power cord (PC).
WLD
8
WLD
:
WLD
9
:+
Power Supply Requirement
110-120 V
15A Circuit Protection
Minimal Power Cord Wire Gauge
Length (FT)
Wire Gauge (AWG)
25
16
50
12
100
10
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
WLD
(
PC
EB
Содержание 25M530
Страница 19: ...Notes 3A5202A 19 Notes ...