TLM Display
6
3A5411J
Configure the TLM
1.
Press the Display button (A) again to
configure the TLM with a new profile.
2.
The display reads CONFIG OK, as
shown in F
configured with the new profile.
If the TLM was not configured with a new
profile by the Pulse software, the error
message CONFIG E8 displays (Step 2,
F
TLM Registration Process
Step 1: Connect Device
Step 2: Load Initial Profile
TLM Display
Registration
Displays REGISTER. Successful registration
adds a second line: OK. Registration failure
adds a second line: ERROR.
Profile
Displays CONFIG. Successful TLM
configuration adds a second line OK.
Unsuccessful TLM configuration adds a
second line ERROR.
Measurement Reporting
Displays REPORT. If data is successfully
transmitted, adds a second line OK. If data is
not successfully transmitted, adds a second
line ERROR.
Sensor Communication Error
If the sensor does not respond to commands
before timeout, a communication error is
flagged. Displays COMM ERR.
Bad Measurement
If there is a communication error during a
read measurement (i.e., timeout), or the
status from the read measurement command
indicates there is an issue, SENSOR ERR #
is displayed. The # corresponds to the
following Sensor Error Table.
SENSOR ERROR TABLE
F
IG
. 3
F
IG
. 4
Error
Description
Sensor E0
Invalid reading or sensor
communication error
Sensor E1
No sensor PCBA detected
(damaged circuit board)
Sensor E4
Invalid profile parameter
Sensor E5
Measurement exceeds maximum
length
Sensor E7
Registration error
Sensor E8
Profile error
Sensor E9
RF communication error (no
acknowledge or no signal)