Warnings

3A4936E

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific 
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where 
applicable.

WARNING

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical 
treatment.

Do not put your hand over the fluid outlet.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or 
servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all 
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information 
about your material, request Safety Data Sheet (SDS) from distributor or retailer.

Do not leave the work area while equipment is energized or under pressure.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create 
safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Содержание 25M212

Страница 1: ...of common industrial paints and coatings in finishing applications For professional use only Model 25M212 3000 psi 21 0 MPa 210 bar Maximum Working Pressure Important Safety Instructions Read all war...

Страница 2: ...Filter Bypass Installation 5 Flush Before Using Equipment 5 Typical Installations 6 Operation 7 Pressure Relief Procedure 7 Troubleshooting 8 Repair 9 Filter Element Replacement 9 Filter O Ring Replac...

Страница 3: ...rious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or temperature rating of the lowest rated system com ponent See...

Страница 4: ...ause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using Store hazardous fluid in approv...

Страница 5: ...ct the fluid through pipes that bypass the filter while is cleaned or serviced 1 Install the filter A and bypass pipes as shown in FIG 1 2 Install four suitable shutoff valves C one each at the filter...

Страница 6: ...2 Supplied by Graco See Parts on page 10 B Fluid Drain Valve 3 4 16 UNF Graco part 248271 Supplied by customer optional C Fluid Shutoff Valve 3 4 14 NPT Supplied by customer D High Pressure Adapter Gr...

Страница 7: ...alve B if used or the filter plug 8 see Parts page 10 located at the bot tom of the filter A See FIG 1 This equipment stays pressurized until pressure is manually relieved from the system To help prev...

Страница 8: ...oblems and causes before dis assembling bowl Problem Cause Solution Leaking around bowl indicator or drain plug Loose fitting Tighten to recommended in lbs See Parts page 10 Broken seal Replace with s...

Страница 9: ...up 6 if material leaks around the bowl 2 1 Follow Pressure Relief Procedure page 7 2 Open the drain valve B and have a container ready to catch the drainage See FIG 1 3 Remove the bowl 2 and o rings 5...

Страница 10: ...ng size 908 Viton 1 5 104445 O ring size 233 Viton 1 6 104443 O ring backup Viton 233 1 7 17L928 Filter compression spring 1 8 17L927 Filter plug 3 4 16 UNF 1 9 Filter element not included see Kits an...

Страница 11: ...Dimensions 3A4936E 11 Dimensions Overall Dimensions Mounting Dimensions...

Страница 12: ...Dimensions 12 3A4936E...

Страница 13: ...a 210 bar Flow capacity 10 gpm 38 liters min Filter Element Filter area 36 sq in 232 cm2 Filtration 108116 60 mesh 250 micron 108117 100 mesh 149 micron 108118 200 mesh 74 micron 104435 no filter elem...

Страница 14: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Отзывы: