Service
Service
Service
Moving parts, such as an impeller blade, can cut
or amputate fingers. To reduce the risk of serious
injury, always shut off the agitator and disconnect
the air line before checking or repairing the agitator.
If the air motor requires more than installation of a
service kit, it is usually quickest and easiest to send it
to a Graco distributor for repair or replacement.
Motor rebuild kits are available and listed in the table
below. See manual 3A5050 for more information.
Kit
Kit
Kit
Description
Description
Description
25M535
Full air motor rebuild kit
25P720
Needle bearing rebuild kit
25P721
Single piston assembly rebuild kit
25P860
End cap kit
19Y509
Muffler kit (set of 3)
Removing
Removing
Removing the
the
the Air
Air
Air Motor
Motor
Motor
Models
Models
Models 25C528,
25C528,
25C528, 25C529,
25C529,
25C529, 25C533,
25C533,
25C533, 25M481
25M481
25M481
1.
Follow the
Pressure Relief Procedure, page 19
.
2.
Remove the air regulator by unscrewing the
swivel fitting (12).
• See
• See
• See
• See
3.
Loosen the upper clamp (2) and raise the motor
so the upper two set screws (3) are accessible.
Use a 1/8 inch hex to remove the set screws
from the shaft.
4.
Lift the air motor straight up off the shaft.
Models
Models
Models 25C534,
25C534,
25C534, 25C535
25C535
25C535
1.
Follow the
Pressure Relief Procedure, page 19
.
2.
Remove the air regulator by
unscrewing the swivel fitting (11). See
Models 25C534, 25C535, page 29
.
3.
Remove the screws (14) holding the motor
mounting plate (13) to the outlet housing (3).
4.
Remove the socket head screws (2) holding the
motor (1) to the mounting plate.
5.
Raise the motor so the two set screws (9) in the
shaft (4) are accessible. Use a 1/8 inch hex to
remove the set screws from the shaft.
6.
Lift the air motor straight up off the shaft.
Model
Model
Model 25C530
25C530
25C530
1.
Follow the
Pressure Relief Procedure, page 19
.
2.
Remove the air regulator by unscrewing the
swivel fitting (9). See
3.
Using a 3/16 inch hex, remove the three set
screws (8) on the bung adapter (4).
4.
Raise the motor so the top two set screws (7) in
the coupler (3) are accessible. Use a 1/8 inch
hex to remove the top two set screws.
5.
Lift the air motor (1) straight up off the coupler.
Models
Models
Models 25N881,
25N881,
25N881, 25N882
25N882
25N882
1.
Follow the
Pressure Relief Procedure, page 19
.
2.
Remove the air regulator by
unscrewing the swivel fitting (5). See
Models 25N881, 25N882, page 31
.
3.
Remove the screws (11) holding the bung
adapter (6) to the motor plate (7).
4.
Lift the motor off the bung adapter (6) and
remove the screws (8) that attach the motor plate
(7) to the motor (1).
3A4792G