Maintenance
Maintenance
Maintenance
Moving parts, such as an impeller blade, can pinch
or amputate fingers. To reduce risk of injury,
always power off and disconnect power from the
VFD before raising, checking, or repairing the
agitator.
Routine
Routine
Routine Periodic
Periodic
Periodic Maintenance
Maintenance
Maintenance
Check and retighten all cap screws every six months
or during down times if they occur more frequently.
Check
Check
Check Screw
Screw
Screw and
and
and Bolt
Bolt
Bolt Tightness
Tightness
Tightness
Within the first two weeks of operation, check all cap
screws and set screws to make sure the screws are
tightened. Retighten as required.
Bearings
Bearings
Bearings
Bearings are sealed and do not require lubrication.
Inspect yearly to verify bearings are running smoothly
and not damaged. Replace if necessary with a new
bearing housing.
Gear
Gear
Gear Reducer
Reducer
Reducer
The gear reducer is filled with synthetic oil and should
be replaced after every 20,000 operating hours or
after every four years. Consult the gear reducer
manual shipped with the gear reducer for instructions
on replacing the lubrication oil.
3A4553F