background image

Parts

NOTE:

NOTE:

NOTE: Many parts are included in one or more kits.
Please see

Kits, page 27

, for the complete list of

available kits and their contents.

Ref

Ref

Ref

Part

Part

Part

Description

Description

Description

Qty

Qty

Qty

1

17F237

BODY

1

2‡

17F072

SLEEVE

1

3‡

17F063

CAP, sleeve

2

4‡

17F071

SLEEVE, center

1

5

17F096

SHAFT, diaphragm

1

COVER, fluid

17F158

PTFE

6

17F164

UHMWPE

2

ADAPTER, inlet, 1/8 in.

17F089

BSPT

7

17F088

NPT

1

MANIFOLD, outlet

17F038

PTFE, BSPT

17F015

UHMWPE, BSPT

17F040

PTFE, NPT

8

17F017

UHMWPE, NPT

1

9

17F243

RETAINER, fluid cover

2

MANIFOLD, inlet

17F039

PTFE, BSPT

17F016

UHMWPE, BSPT

17F041

PTFE, NPT

10

17F018

UHMWPE, NPT

1

11

17F165

RETAINER, manifold

2

12

17F241

PLATE, base

2

13

17F216

PLUG, manifold

2

14

17F077

CAP, muffler

1

15‡

17F080

MUFFLER, felt; 4–pack

1

16‡

17F195

SEAL, glide sleeve;
6–pack

1

17‡

17F196

SEAL, glide shaft;
4–pack

1

18

17F187

NUT, fluid cover

8

19†

17F100

RETAINER, ball, 1/2 in.,
outlet (top); PTFE

2

Ref

Ref

Ref

Part

Part

Part

Description

Description

Description

Qty

Qty

Qty

20†

17F104

RETAINER, ball, 1/2 in.,
inlet (bottom); PTFE

2

21†

--

SEAT

4

22†

17F252

BALL, 1/2 in.; PTFE;
4–pack

1

24

17F181

BOLT, tie; stainless steel

6

DIAPHRAGM, 2–pack

17F245

Buna-n

17F246

EPDM

25†

17F247

PTFE

1

26

17F193

WASHER, 4 mm;
20–pack

1

27

17F194

WASHER, belleville,
0.375 in. diameter;
50–pack

1

28

17F179

NUT, hex, M4 x 0.7;
stainless steel

12

29

17F180

SCREW, socket head,
M4 x 0.7 x 60 mm;
stainless steel

8

30

17F190

FEET, pump; nitrile;
4–pack

1

31

17F197

O-RING, #12; EPDM;
2–pack

1

32‡

17F198

O-RING, #13; EPDM;
5–pack

1

33‡

17F230

O-RING, #18; EPDM;
7–pack

1

34‡

17F200

O-RING, #20; EPDM;
5–pack

1

35

17F201

O-RING, #21; EPDM;
2–pack

1

36‡

17F231

RING, #23; EPDM;
2–pack

1

37†

17F225

PLUG, cap, 0.47
diameter; 20–pack

1

38

17F079

SPACER, baffle; mesh;
3–pack

1

334793A

25

Содержание 24X427

Страница 1: ...use use only only only Not Not Not approved approved approved for for for use use use in in in European European European explosive explosive explosive atmosphere atmosphere atmosphere locations loca...

Страница 2: ...ore First Use 13 Start and Adjust the Pump 13 Pressure Relief Procedure 14 Pump Shutdown 14 Maintenance 15 Maintenance Schedule 15 Lubrication 15 Tighten Threaded Connections 15 Flushing and Storage 1...

Страница 3: ...rounding Grounding instructions Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Sto...

Страница 4: ...ards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cable...

Страница 5: ...ing to applicable guidelines BURN BURN BURN HAZARD HAZARD HAZARD Equipment surfaces and fluid that s heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipme...

Страница 6: ...Pump Center Center Center Section Section Section and and and Air Air Air Valve Valve Valve Material Material Material Fluid Fluid Fluid Covers Covers Covers and and and Manifolds Manifolds Manifolds...

Страница 7: ...ed Overmolded Overmolded 24X534 24X534 24X534 bspt bspt bspt 24X535 24X535 24X535 npt npt npt EPDM EPDM EPDM 24X506 24X506 24X506 bspt bspt bspt 24X505 24X505 24X505 3 8 3 8 3 8 in in in PTFE PTFE PTF...

Страница 8: ...educe Reduce Reduce Cavitation Cavitation Cavitation Cavitation in an AODD pump is the formation and collapse of bubbles in the pumped liquid Frequent or excessive cavitation can cause serious damage...

Страница 9: ...For all mountings be sure the pump is secured with screws through the mounting feet Always mount the pump upright 4 Make sure the surface is flat and that the pump doesn t wobble 5 For ease of operat...

Страница 10: ...flushing Follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continui...

Страница 11: ...t exhaust 1 Use Kit 17F610 NPT or 17F611 BSPT sold separately 2 Remove the muffler U from the pump air exhaust port K 3 Install the adaptor from the kit 4 Install a grounded air exhaust hose S If a ho...

Страница 12: ...orten diaphragm life Approximately 3 5 psi 0 02 0 03 MPa 0 21 0 34 bar should be adequate for most materials 3 For maximum suction lift wet and dry see Technical Data page 31 For best results always i...

Страница 13: ...ounded See Ground The System page 10 2 Check fittings to be sure they are tight Use a compatible liquid thread sealant on male threads NOTICE NOTICE NOTICE Do not overtighten fluid inlet and outlet fi...

Страница 14: ...ng in the eyes or on skin follow the Pressure Relief Procedure when you stop pumping and before you clean check or service the equipment 1 Shut off the air supply to the pump 2 Open the dispensing val...

Страница 15: ...ght and leak free Check mounting bolts Check bolts Tighten or retorque as necessary Although pump use varies a general guideline is to retorque bolts every two months See Torque Instructions page 22 F...

Страница 16: ...damaged Replace spool valve Check valve ball is severely worn or wedged in seat or manifold Replace ball and seat Dispensing valve is clogged Relieve pressure and clear valve Pump will not cycle or c...

Страница 17: ...ity Use drier air supply Pump exhausts excessive air at stall Spool valve seals are worn or damaged Replace Fluid covers are loose Retorque Diaphragm is damaged Replace Pump leaks air externally Manif...

Страница 18: ...l retainer 20 4 Rethread the manifold bolts 29 to keep the fluid cover nuts 18 aligned Turn over the pump 5 Use a 3 mm Allen wrench to remove the outlet manifold 8 and retainer 11 6 Repeat Step 3 to r...

Страница 19: ...Install a plug 40 in each of the three unused ports 1 Install the muffler media into the muffler Use the new felt mufflers 15 supplied in the rebuild kit Muffler parts must be placed in the exact orde...

Страница 20: ...e fluid covers with the top checks toward the air inlet 5 Place two belleville washers 27 with the washer closest to the nut having the rounded side toward the nut and the other washer with the rounde...

Страница 21: ...e the manifold bolts 29 from the top of the fluid covers 6 keeping nuts 18 aligned 14 Assemble the top checks Insert the seat 21 with the chamfered side up the ball 22 and the outlet ball retainer 19...

Страница 22: ...ifolds 1 Remove the protective bolt covers 37 with a screwdriver Carefully work the screwdriver under the lip of each cap and gently pry it off 2 Start all fluid cover screws a few turns Then turn dow...

Страница 23: ...Notes Notes Notes Notes 334793A 23...

Страница 24: ...Parts Parts Parts Parts 24 334793A...

Страница 25: ...t 4 pack 1 16 17F195 SEAL glide sleeve 6 pack 1 17 17F196 SEAL glide shaft 4 pack 1 18 17F187 NUT fluid cover 8 19 17F100 RETAINER ball 1 2 in outlet top PTFE 2 Ref Ref Ref Part Part Part Description...

Страница 26: ...Part Part Part Description Description Description Qty Qty Qty 45 17F794 TOOL wrench sleeve cap 1 46 17F795 TOOL wrench muffler cap 1 47 17F215 STUD threaded 2 Replacement Warning labels signs tags an...

Страница 27: ...bly Assembly Assembly Kit Kit Kit 17F589 17F589 17F589 Kit includes Ref Ref Ref Description Description Description Qty Qty Qty 4 Center Sleeve 2 16 Glide Sleeve Seal 7 17 Glide Shaft Seal 6 Ref Ref R...

Страница 28: ...sions Ref Ref Ref US US US Metric Metric Metric A A A 1 1 in 28 mm B B B 5 3 in 135 mm C C C 3 0 in 76 mm D D D 5 9 in 150 mm Ref Ref Ref US US US Metric Metric Metric E E E 4 9 in 124 mm F F F 7 6 in...

Страница 29: ...Dimensions Mounting Mounting Mounting Layout Layout Layout H H H 3 0 in 76 mm J J J 3 0 in 76 mm K K K hole hole hole diameter diameter diameter 0 3 in 7 mm 334793A 29...

Страница 30: ...A A A 100 psi 0 7 MPa 7 0 bar B B B 70 psi 0 48 MPa 4 8 bar C C C 40 psi 0 28 MPa 2 8 bar Air Air Air Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per p...

Страница 31: ...operated in low temperature environments Take care to avoid freezing or crystallization of the fluid inside or outside of the pump Running the pump at temperatures below freezing may accelerate the we...

Страница 32: ...CO MAKES MAKES MAKES NO NO NO WARRANTY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHAN...