background image

Warnings

WARNING

WARNING

WARNING

EQUIPMENT

EQUIPMENT

EQUIPMENT MISUSE

MISUSE

MISUSE HAZARD

HAZARD

HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated

system component. See Technical

Technical

Technical Data

Data

Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical

Technical

Technical Data

Data

Data

in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request MSDS from distributor or retailer.

• Do not leave the work area while equipment is energized or under pressure.
• Turn off all equipment and follow the Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine

manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals

and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.

THERMAL

THERMAL

THERMAL EXPANSION

EXPANSION

EXPANSION HAZARD

HAZARD

HAZARD

Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure
due to the thermal expansion. Over-pressurization can result in equipment rupture and serious
injury.

• Open a valve to relieve the fluid expansion during heating.
• Replace hoses proactively at regular intervals based on your operating conditions.

PLASTIC

PLASTIC

PLASTIC PARTS

PARTS

PARTS CLEANING

CLEANING

CLEANING SOLVENT

SOLVENT

SOLVENT HAZARD

HAZARD

HAZARD

Many solvents can degrade plastic parts and cause them to fail, which could cause serious
injury or property damage.

• Use only compatible water-based solvents to clean plastic structural or pressure-containing

parts.

• See Technical

Technical

Technical Data

Data

Data in this and all other equipment instruction manuals. Read fluid and

solvent manufacturer’s MSDSs and recommendations.

4

334796G

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Содержание 24X421

Страница 1: ...ed approved for for for use use use in in in European European European explosive explosive explosive atmosphere atmosphere atmosphere locations locations locations Important Important Important Safet...

Страница 2: ...Pump Shutdown 14 Maintenance 15 Maintenance Schedule 15 Lubrication 15 Tighten Threaded Connections 15 Flushing and Storage 15 Troubleshooting 16 Repair 18 Disassemble the Fluid Section 18 Replace the...

Страница 3: ...es Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Stop operation operation operation immediately immediate...

Страница 4: ...r the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts an...

Страница 5: ...ZARD HAZARD Equipment surfaces and fluid that s heated can become very hot during operation To avoid severe burns Do not touch hot fluid or equipment PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE P...

Страница 6: ...Air Air Valve Valve Valve Material Material Material Fluid Fluid Fluid Covers Covers Covers and and and Manifolds Manifolds Manifolds 1590 1590 1590 PT PT PT 1 5 in PTFE P01A P01A P01A Polypropylene...

Страница 7: ...Balls Balls Balls Diaphragm Diaphragm Diaphragm Manifold Manifold Manifold Seal Seal Seal 24X422 bspt 24X421 1 5 in PTFE npt PTFE 24X486 bspt 24X485 npt PTFE EPDM Overmolded 24X549 bspt 24X551 npt EPD...

Страница 8: ...Cavitation in an AODD pump is the formation and collapse of bubbles in the pumped liquid Frequent or excessive cavitation can cause serious damage including pitting and early wear of fluid chambers ba...

Страница 9: ...e pump is secured with screws through the mounting feet Always mount the pump upright 3 Make sure the surface is flat and that the pump doesn t wobble 4 For ease of operation and service mount the pum...

Страница 10: ...pails placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity Check your system electrical continuity after the...

Страница 11: ...T sold separately 2 Remove the muffler U from the pump air exhaust port K 3 Install the adaptor from the kit 4 Install a grounded air exhaust hose S If a hose longer than 10 ft 3 m is required use a l...

Страница 12: ...MPa 0 21 0 34 bar should be adequate for most materials 3 For maximum suction lift wet and dry see Technical Data page 31 For best results always install the pump as close as possible to the material...

Страница 13: ...ngs to be sure they are tight Use a compatible liquid thread sealant on male threads NOTICE NOTICE NOTICE Do not overtighten fluid inlet and outlet fittings Soft plastic threads can be stripped easily...

Страница 14: ...Procedure when you stop pumping and before you clean check or service the equipment 1 Shut off the air supply to the pump 2 Open the dispensing valve if used 3 Open the fluid drain valve to relieve fl...

Страница 15: ...ghten or retorque as necessary Although pump use varies a general guideline is to retorque bolts every two months See Torque Instructions page 24 Flushing Flushing Flushing and and and Storage Storage...

Страница 16: ...ld Replace ball and seat Dispensing valve is clogged Relieve pressure and clear valve Pump will not cycle or cycles once and stops Diaphragm is ruptured Replace Suction line is clogged Inspect clear C...

Страница 17: ...r damaged Replace Fluid covers are loose Retorque Diaphragm is damaged Replace Pump leaks air externally Manifold fittings are loose Retorque Fluid covers are loose Retorque Pump leaks fluid externall...

Страница 18: ...lace use a hook to remove without scratching the inner bore 5 Turn over the pump and use a 13 mm socket to remove the manifold retainer 11 and the outlet manifold 8 6 Inspect both inlet manifold s 10...

Страница 19: ...p use a 3 16 in hex wrench to remove the four screws 33 securing the anchor strap 31 to the fluid cover retainer 9 3 Align the four holes in the new anchor strap 31 with the corresponding holes in the...

Страница 20: ...r Air Air Motor Motor Motor 1 Use pin wrench 43 to remove the air motor assembly 2 to remove from the body 1 2 Inspect o rings 34 and replace if necessary 3 Apply a thin film of lubricant 44 to air mo...

Страница 21: ...Press each spool 3 individually to verify that the other spool 3 has a corresponding shift d Plug the air holes on the air motor 2 to verify no air is escaping from either of the spools 3 6 Install t...

Страница 22: ...lace two belleville washers 27 with the rounded side of first washer toward the permanently attached nut and the rounded side of the second washer away from the nut then a flat 12 washer 26 4 Slide th...

Страница 23: ...a ball retainer 20 check ball 22 d ring 21 and o ring 17 into the inlet side of each fluid cover 6 12 Align the inlet manifold 10 on the assembly Use the placement of dowel pins 23 to orient the manif...

Страница 24: ...screwdriver Carefully work the screwdriver under the lip of each cap and gently pry it off 2 Start all fluid cover screws a few turns Then turn down each screw just until head contacts cover 3 Turn ea...

Страница 25: ...e using PFPE grease 17G558 included in all Center and Fluid Section Rebuild kits 2 Follow Torque Instructions page 24 334796G 25 Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www spring...

Страница 26: ...2 15 17F081 MUFFLER felt 2 pack 2 16 17F306 SCREW button hd M8 x 1 x 80 lg 4 17 17F320 SEAL o ring 331 PTFE 4 pack 1 18 17F186 NUT manifold 16 Ref Ref Ref Part Part Part Description Description Descri...

Страница 27: ...Qty Qty Qty 42 17F796 TOOL wrench spool removal 4 pin 1 43 17F800 TOOL wrench air motor 1 44 17G558 LUBRICANT PFPE 1 Replacement Warning labels signs tags and cards are available at no cost Parts inc...

Страница 28: ...Qty Qty 4 Strike Plate 2 5 Shaft 1 17 331 O ring 4 Wearable Seat PTFE Kits 17F140 17G053 17G054 19 UHMW Kits 17F142 17F143 17F145 2 Ball Retainer PTFE Kits 17F140 17G053 17G054 20 UHMW Kits 17F142 17F...

Страница 29: ...C C C 7 8 in 19 8 cm D D D 15 5 in 39 3 cm E E E 13 1 in 33 2 cm F F F 20 0 in 50 8 cm G G G 9 8 in 24 9 cm K K K 9 1 in 23 1 cm L L L 11 1 in 28 2 cm M M M hole hole hole diameter diameter diameter 0...

Страница 30: ...ir Consumption Consumption Consumption Approximate Approximate Approximate Cycles Cycles Cycles per per per Minute Minute Minute How How How to to to Read Read Read the the the Charts Charts Charts 1...

Страница 31: ...crystallization of the fluid inside or outside of the pump Running the pump at temperatures below freezing may accelerate the wear of the elastomer components in the pump 32 F 0 C Air consumption at...

Страница 32: ...D AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FO...

Отзывы: