Maintenance
334198K
15
Maintenance
Monthly Maintenance
Periodically (approximately once a month) inspect the
ram guide sleeves, rods, and cylinders for wear or dam-
age; replace all worn parts.
Check the hydraulic fluid level. Add more hydraulic fluid
if the fluid level falls lower than 4 in. (102 mm) from the
top of the fluid gauge. See
Checking the Hydraulic Fluid
Level
Check the hydraulic fluid level in the supply unit. The
fluid level should be approximately 2–4 in. (51–102 mm)
from the top of the fluid level gauge (3). If necessary,
perform the following steps to add more hydraulic fluid:
1. Unscrew the breather (4).
2. Pour hydraulic fluid through the breather hole (13).
3. Replace the breather. See F
NOTE:
Make sure hydraulic tank is filled to the correct
level. Overfilling tank can cause hydraulic fluid to spill
out the breather. See F
Changing the Hydraulic Fluid
Filter
The filter element (19) of the hydraulic fluid assembly
may become clogged with manufacturing residue after
the first 40 hours of operation. Change the filter element
after the first 40 hours of operation. For information
about starting up the rest of the system, refer to the
Therm-O-Flow 200 and Therm-O-Flow 20, Instruc-
tions-Parts manuals. See F
F
IG
. 11
WLE
F
IG
. 12
F
IG
. 13
FILL
LEVEL
Over Filled
Correctly
Filled
Under Filled
WLD
Содержание 24W181
Страница 13: ...Setup 334198K 13...
Страница 20: ...Parts 20 334198K 24W184 Therm O Flow 200 Hydraulic WL D 6 7 21 7 F...
Страница 24: ...Parts 24 334198K 24V757 Hydraulic Reservoir 1 Apply pipe sealant to all male pipe threads WL E FILL LEVEL...
Страница 26: ...Dimensions 26 334198K Dimensions FIG 14 Model 24W183 Model 24W184 WLL D WL E...
Страница 27: ...Dimensions 334198K 27 FIG 15 Model 24W181 WLL D xx WL D...