Setup
8
334198K
Setup
Refer to the Therm-O-Flow 200 and Therm-O-Flow 20,
Instructions-Parts manuals for additional setup proce-
dures such as unpacking, location requirements, and
component installations.
Grounding
Refer to the Therm-O-Flow 200 and Therm-O-Flow 20,
Instructions-Parts manuals for the grounding of the unit.
Grounding the Hydraulic Power
Supply
To ground the hydraulic power supply unit pump, con-
nect the ground wire and clamp to a true earth ground
as shown.
1. Loosen the grounding screw and washer.
2. Insert one end of the 1.5 mm (12 gauge) minimum
ground wire into the slot in the lug and tighten the
locknut securely.
3. Connect the other end of the wire to a true earth
You must also provide an earth ground to the supply
unit electrical control box. Make sure the ram is installed
correctly to ensure that the ram is properly grounded.
For information about grounding other components in
your system, see the system or supply unit documenta-
tion, as well as the documentation for individual compo-
nents.
The equipment must be grounded to reduce the risk of
static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
F
IG
. 4
WLD
Содержание 24W181
Страница 13: ...Setup 334198K 13...
Страница 20: ...Parts 20 334198K 24W184 Therm O Flow 200 Hydraulic WL D 6 7 21 7 F...
Страница 24: ...Parts 24 334198K 24V757 Hydraulic Reservoir 1 Apply pipe sealant to all male pipe threads WL E FILL LEVEL...
Страница 26: ...Dimensions 26 334198K Dimensions FIG 14 Model 24W183 Model 24W184 WLL D WL E...
Страница 27: ...Dimensions 334198K 27 FIG 15 Model 24W181 WLL D xx WL D...