Installation
Installation
Installation
Installation
Before
Before
Before Installing
Installing
Installing the
the
the Kit
Kit
Kit
• Servicing the electrical control box exposes you
to high voltage. To avoid electric shock, turn off
power at the main circuit breaker before opening
the enclosure.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
• This equipment must be grounded to reduce the
risk of static sparking and electric shock, which
could cause fumes to ignite or explode. See
Grounding, page 16
.
Follow the Pressure Relief Procedure in
your PD2K manual whenever you see
this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid such as skin injection,
splashing fluid, and moving parts, follow the
Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure in your system manual
when you stop spraying and before cleaning,
checking, or servicing the equipment.
1.
Flush the system as explained in your PD2K
Operation Manual. Follow the Pressure Relief
Procedure in your PD2K manual.
2.
Close the main air shutoff valve on the air supply
line.
3.
Remove electrical power from the system.
Install
Install
Install the
the
the Pump
Pump
Pump
The electronic portion of the pump kit must remain
outside the hazardous location. See Figure 2.
1.
Follow the steps in Before
Before
Before Installing
Installing
Installing the
the
the Kit,
Kit,
Kit, in the
previous section.
2.
Plan your installation so that all pumps are
located within 6 ft. of the PD2K electrical control
box (D). Each multi-conductor cable (10) must
be able to reach from the dual cable grommet
(9) to one of the ports on the control box. See
Electrical Connections, page 14
. See also Figure
2.
NOTE:
NOTE:
NOTE: To mount pumps on both sides of the
control box, turn the pump control module (6)
over, and connect the dual cable grommet (9) on
the other side of the rear mounting bracket.
3.
Install the pump assembly securely by bolting
the rear mounting bracket (4) to desired wall or
sturdy surface. See
Dimensions, page 32
.
4.
Apply approved fireproof sealant to the mating
surface of the mounting plate (1), to ensure
an airtight seal. Mount the plate on the
horizontal surface that is the barrier between
the hazardous and non-hazardous areas. See
Dimensions, page 32
.
334512C
9