Maintenance
38
333347F
4.
When the melter temperature is the desired tem-
perature, turn main power switch OFF.
5.
Disconnect cable from ADM, push cable through
plastic shroud, then remove plastic shroud from sys-
tem.
6.
Place a piece of cardboard beneath the inlet filter
cap (215) to route fluid away from system into a
waste container in the event the adhesive is a fluid.
7.
Use 1 in. socket to remove inlet filter cap (215).
8.
If the adhesive is a thin enough gel to remove the
inlet filter:
Use an o-ring pick or small allen wrench
to remove filter screen (213) from system.
Otherwise:
a.
Install inlet filter cap (215).
b.
Install shroud and ADM.
c.
Turn main power switch ON.
d.
Once ADM software finishes starting up,
press
to enable the heaters.
e.
Wait for temperature to rise 20°F (11°C) beyond
previous temperature.
f.
Go to step 4.
9.
Slide new screen (213) into melter base
manifold (201).
10. Install filter cap (215) then use a 1 in. socket to
tighten.
11. Feed ADM cable through plastic shroud (29) then
install shroud onto system. Connect cable to
ADM (30).
Replace Funnel Filter
Disassembly (see F
1.
Turn main power switch OFF.
2.
Rotate funnel cap (706) and remove. Lift out funnel
filter (705).
Reassembly (see F
. 27):
1.
Insert filter (705) in funnel assembly. Tighten funnel
cap (706) on funnel.
F
IG
. 26
WLD
215
213
201
F
IG
. 27
WLD
706
705