background image

Important Isocyanate (ISO) Information

332198C

5

Important Isocyanate (ISO) Information

Isocyanates (ISO) are catalysts used in two component materials. 

Isocyanate Conditions

 

 

Material Self-ignition

 

Keep Components A (ISO) and 
B (RES) Separate

 

Moisture Sensitivity of 
Isocyanates

Exposure to moisture (such as humidity) will cause ISO 
to partially cure; forming small, hard, abrasive crystals, 
which become suspended in the fluid. Eventually a film 
will form on the surface and the ISO will begin to gel, 
increasing in viscosity. 

NOTE: The amount of film formation and rate of crystal-
lization varies depending on the blend of ISO, the 
humidity, and the temperature.

Foam Resins with 245 fa 
Blowing Agents

Some foam blowing agents will froth at temperatures 
above 90°F (33°C) when not under pressure, especially 
if agitated. To reduce frothing, minimize preheating in a 
circulation system.

Spraying or dispensing materials containing isocya-
nates creates potentially harmful mists, vapors, and 
atomized particulates.

Read material manufacturer’s warnings and material 
MSDS to know specific hazards and precautions 
related to isocyanates.

Prevent inhalation of isocyanate mists, vapors, and 
atomized particulates by providing sufficient ventila-
tion in the work area. If sufficient ventilation is not 
available, a supplied-air respirator is required for 
everyone in the work area.

To prevent contact with isocyanates, appropriate per-
sonal protective equipment, including chemically 
impermeable gloves, boots, aprons, and goggles, is 
also required for everyone in the work area.

Some materials may become self-igniting if applied 
too thick. Read material manufacturer’s warnings and 
material MSDS.

Cross-contamination can result in cured material in 
fluid lines which could cause serious injury or damage 
equipment. To prevent cross-contamination:

Never interchange component A (ISO) and com-
ponent B (RES) wetted parts. 

Never use solvent on one side if it has been con-
taminated from the other side.

NOTICE

Partially cured ISO will reduce performance and the 
life of all wetted parts. 

Always use a sealed container with a desiccant 
dryer in the vent, or a nitrogen atmosphere. Never 
store ISO in an open container.

Keep the ISO pump wet cup or reservoir (if 
installed) filled with appropriate lubricant. The 
lubricant creates a barrier between the ISO and 
the atmosphere.

Use only moisture-proof hoses compatible with 
ISO.

Never use reclaimed solvents, which may contain 
moisture. Always keep solvent containers closed 
when not in use.

Always lubricate threaded parts with an appropri-
ate lubricant when reassembling.

Содержание 24R021

Страница 1: ...ds of non abrasive material For professional use only Not approved for use in European explosive atmosphere locations Model 24R021 2000 psi 14 MPa 137 bar Maximum Fluid Working Pressure Important Safe...

Страница 2: ...Operation 8 Prime 8 Pressure Balance the Gun 8 Ratio Checking 9 Install Disposable Static Mixer 9 Dispense 9 Pressure Relief Procedure 10 Daily Shutdown 10 Flushing 10 Install Restrictors or Plugs 11...

Страница 3: ...om dispensing device hose leaks or ruptured components will pierce skin This may look like just a cut but it is a serious injury that can result in amputation Get immediate surgical treatment Do not p...

Страница 4: ...ts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you...

Страница 5: ...by providing sufficient ventila tion in the work area If sufficient ventilation is not available a supplied air respirator is required for everyone in the work area To prevent contact with isocyanate...

Страница 6: ...rials flush the equipment multiple times to ensure it is thoroughly clean Always clean the fluid inlet strainers after flushing Check with your material manufacturer for chemi cal compatibility When c...

Страница 7: ...blue for component B RES Red ISO usually is connected to the left side of the valve as viewed from the back of the gun 5 Perform Prime procedure page 8 GROUNDING The equipment must be grounded to red...

Страница 8: ...ntinue to next step If not pressures are sufficiently balanced 4 If pressures are more than 25 apart replace one or both plugs or restrictors with a different restrictor size NOTE An extra 0 032 in re...

Страница 9: ...gun has not yet been pressure balanced per form Pressure Balance the Gun procedure on page 8 3 If the fluid in the static mixer is cured or there is no static mixer installed Install Disposable Static...

Страница 10: ...n you finish using the 2K Manual Dispense Valve clean the outlet manifold F and protect it from drying or crystallization as follows 1 Perform Pressure Relief Procedure page 10 2 Remove and properly d...

Страница 11: ...check valve oscillation causes ratio imbalance Install restrictors on both sides to meter a smooth flow to the manifold Sizing Restrictors If resin and hardener are at or near 1 1 ratio and viscos iti...

Страница 12: ...ion temperature range Change restrictor at mix point to balance back pressure Restriction on one side Clean mix module restrictors or check valves at mix manifold A ISO side rich lack of B RES side A...

Страница 13: ...when viewed from the rear of the gun Squarely align outlet manifold 6 to inlet manifold 1 Apply lithium grease Torque restrictors 18 to 40 50 in lb 4 5 5 6 N m Hand tighten mixer nut 7 onto outlet man...

Страница 14: ...ength of the gun from 47 in 1194 mm to 24 in 610 mm purchase two of each of the following fittings 503279 and 151243 Use these fit tings to replace fittings 4 and tubes 5 Standard Disposable Mixer Alt...

Страница 15: ...77 15E376 15E375 15E374 15E373 15E372 Restrictor Diameter and Part No Key 5000 cps 1 0 gpm 3 8 lpm 5000 cps 0 25 gpm 0 95 lpm 1000 cps 0 25 gpm 0 95 lpm 500 cps 0 25 gpm 0 95 lpm 200 cps 0 25 gpm 0 95...

Страница 16: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Отзывы: