Maintenance
26
3A0590R
Maintenance
Follow
the when you
stop spraying or dispensing and before cleaning,
checking, servicing, or transporting equipment.
Clean Static Mixers
See F
. 1 on page 9. Typically, two static mixer
housings are connected to the mix manifold outlet (H).
These housings use plastic mix elements, available in a
package of 25 (Part No. 248927).
To clean the housing and replace the mix element:
1. Follow the
on page 21.
2. Remove mixer housings (J) from whip hose (K).
3. Place flats of mixer housing (J) in a vise. Push mix
element (P) out of the inlet end.
4. If necessary, use a 1/2 in. drill bit to drill out old
material and the mix element from the inlet end,
down to the internal shoulder at the outlet end.
5. Use a brush to clean any debris in housing (J).
6. Insert new mix element, wide end first.
Clean “B” Side Screen
19
21
20
18
17
The following instructions apply only when using the
strainer accessory for low viscosity fluids. See
on page 36.
1. Loosen swivels (19) and remove shutoff handle (21)
and valves (20). See F
IG
. 7.
2. Remove “B” inlet union (19) from manifold block (1).
3. Pull “V” screen (17) and retainer o-ring (18) straight
up and out with a needle nose pliers.
4. Clean or replace screen (17).
5. Reinstall screen (17) and o-ring (18) with accessory
tool 15T630.
The o-ring (18) is used as a retainer ring, not a seal. It
may be scratched or deformed from pushing the screen
(17) back in.
6. Install “B” inlet union (19) from manifold block (1).
Clean Mix Manifold Outlet
5
4
1. Remove outlet fitting (5) to expose “B” center
injection tube (4).
2. Clean any build-up on, around, or inside the tube
(4).
3. Reinstall outlet fitting (5).
End of Product Life
At the end of a product’s useful life, recycle it in a
responsible manner.
NOTICE
Never use a swivel union on the mixer inlets. The
union will compress the tube and make it
impossible to remove the mix element.