Installation
16
3A0590R
Installation
For assistance in setting up a plural component sprayer,
contact your Graco distributor, to ensure that you select
the proper type and size equipment for your system.
A and B Material Inlets
Standard XP Mix Manifold 262807 (See illustration in
F
. 1 on page 9) and Quickset Mix Manifold 24M398:
The A and B material inlets (AA and AB) are equipped
with 1/2 npt(f) ball valves. Connect 1/2 in., 3/8 in., or 1/4
in. npsm(f) fluid hoses with adapter nipples as needed.
Solvent Inlet
For Standard XP Mix Manifold 262807:
Connect the
solvent extension hose (H) to the solvent supply hose
(G). Connect the other end of the solvent extension
hose (H) to the solvent inlet (AC).
For Quickset Mix Manifold 24M398:
Connect the
solvent supply hose (G) to the solvent inlet tee (DF).
Use a Graco approved grounded hose rated to
withstand the maximum fluid working pressure of the
solvent pump. The hose core must be chemically
compatible with the solvent being used, such as nylon or
PTFE.
Mixed Material Outlet
-0
30
-0
WLD
Standard XP Mix Manifold 262807
Connect the outlet to two primary static mixer tubes (J),
with mixer elements (M), to the mix hose (N), cleanup
mixer (P), whip hose (K), and spray gun (L).
Quickset Manifold 24M398
Connect the whip hose (DJ), adapter fitting (DK) and
spray gun (DL).
NOTICE
To prevent creating a flare on the mixer tube, do not
use a union swivel end on the mix tube inlet.
NOTICE
To prevent material from curing inside the manifold,
never split the flow to multiple guns until the two
fluids are mixed after the mix manifold assembly.
Содержание 24M398
Страница 31: ...Repair 3A0590R 31 ...