Installation
8
3A1189B
1.
Connect suction tube (6c) to drum insert (6b) to
pump.
2.
Insert suction line (6c) into drum.
NOTE:
Do not trim the suction tube. It is designed to
bend when inserted to ensure maximum fluid can be
extracted from the drum.
3.
Install drum coupler (6a) into drum insert (6b)
4.
Connect hose (E) to pump fitting. Use a flat-blade
screw driver to tighten hose clamp (F).
5.
Connect the air supply line (C) to the air controls.
Nozzle (3) and Meter (10) Installation
Numerals used in the following instructions refer to refer-
ence numbers used in the Parts Lists provided on pages
10 - 12.
Wall Mount Models 24F878 or 24F878 -
Installing Nozzle (3) and Meter Kit 24H293 (10)
NOTE:
Meters are only used on model 24F531.
Meter Kit 24H293 includes the following parts - Meter
(10a), Swivel (10b), Fitting (10c) and Seal (10d) and Fit-
ting (10e).
Model 24F878
1.
Install hose (9) into back of nozzle (3). Wrench
tighten.
2.
Install other end of hose (9) into pump outlet fitting.
Model 24F531 Only:
1.
Install hose (9) into back of nozzle (3). Wrench
tighten.
2.
Install pipe swivel fitting (10b) into pump outlet.
Wrench tighten.
3.
Install fitting (10c) into swivel (10b). Wrench tighten.
4.
Install meter (10a) to fitting (10c). Wrench tighten.
5.
Install fitting (10e) into meter. Wrench tighten.
6.
Install hose (9) into fitting (10e).
Drum Mount Model 24F947 -
Installing Nozzle (3)
1.
Install clamp over end of fluid supply hose (9).
2.
Push end of fluid supply hose (9) over end of nozzle
(3) fitting.
3.
Position clamp over fitting and hose end. Use a flat
blade screw driver to tighten screw and secure
clamp to the end of hose over barbed fitting.
4.
Install other end of hose (9) into pump outlet fitting.
Mounting Bracket (2) Installation
•
When installing bracket, be sure the mounting sur-
face can support the weight of the pump, hoses and
all accessories, as well as the stress caused during
operation.
•
On all installations mount the pump using screws
and nuts provided.
•
Always keep nozzle bath tray filled with water.
Wall Mounting Kit 24F870 (2): Models 24F531 and
24F878 only
Wall mounted DEF System Models 24F531 and 24F878
include a Mounting Bracket Kit containing the following
parts - Screws (2a), Screws (2b), Washers (2c), Plain
Washers (2d), Hex Nuts (2e), Mounting Plate (2f), Noz-
zle Bath Holder (2g), Nozzle Holder Bracket (2h) and
screws (2j). The Mounting Bracket and Nozzle Holder
are also identified as items J and M on the Typical Instal-
lation Diagram provided on page 4.
1.
Determine location to install mounting plate (2f).
F
IG
. 5
6c
6b
6a
E
F