Installation
309930C
3
Installation
. 2 for the following instruction.
1.
Install 12-gauge red wires #1750 and #1730 into
new connector (J).
2.
Once pins are inserted, install clamp to hold pins to
connector.
3.
Cut 2 in. off both wires (O, P).
4.
Strip 9/16 in. of insulation with 12-gauge wire
stripper.
5.
Inspect wires. If not black or in burnt condition,
continue to step 6. If wires appear black or in burnt
condition, repeat steps 3 and 4. Do not exceed 6 in.
7.
Install splice onto the strands of each wire. Tighten
screw terminal onto each wire.
9.
Slide shrink tubing over splices.
10. Using a heat gun or hair dryer, heat shrink tubing
around splice. If neither is available, wrap entire
length of shrink tubing with electrical tape.
11. Connect 2-pin black plastic connectors together.
F
IG
. 2: Installation of new harness
H
J
K
To white
terminal block
To circuit board
Red wires
TI5690A
6.
Install shrink tubing over both wires.
Shrink tubing
Transformer
D
C
8.
Insert wires (O, P) into other end of splice and
tighten.
Shrink
tubing
Splice
Transformer
O
P
2-pin black
connector
D
C
Содержание 248113
Страница 5: ...Installation 309930C 5...