background image

Installation

309930C

3

Installation

Use F

IG

. 2 for the following instruction.

1.

Install 12-gauge red wires #1750 and #1730 into 
new connector (J). 

2.

Once pins are inserted, install clamp to hold pins to 
connector.

3.

Cut 2 in. off both wires (O, P).

4.

Strip 9/16 in. of insulation with 12-gauge wire 
stripper.

5.

Inspect wires. If not black or in burnt condition, 
continue to step 6. If wires appear black or in burnt 
condition, repeat steps 3 and 4. Do not exceed 6 in.

7.

Install splice onto the strands of each wire. Tighten 
screw terminal onto each wire.

9.

Slide shrink tubing over splices.

10. Using a heat gun or hair dryer, heat shrink tubing 

around splice. If neither is available, wrap entire 
length of shrink tubing with electrical tape.

11. Connect 2-pin black plastic connectors together.

F

IG

. 2: Installation of new harness

H

J

K

To white 
terminal block

To circuit board

Red wires

TI5690A

6.

Install shrink tubing over both wires.

Shrink tubing

Transformer

D

C

8.

Insert wires (O, P) into other end of splice and 
tighten.

Shrink 
tubing

Splice 

Transformer

O

P

2-pin black 
connector

D

C

Отзывы: