Reassembly
309577A
15
14.
To reconnect pump A:
a.
Turn main power ON
.
b.
Press
. Motor will run until compo-
nent A connecting rod is at bottom of its
stroke, then shut off. Pump B moves to
top of stroke; pumps must be opposed
(1 up, 1 down) for Reactor to run.
c.
Shut main power OFF
.
d.
Ensure locknut (G) is screwed on pump
with flat side up. Screw pump into bear-
ing housing (M) until pin holes align.
Push pin (F) in. Pull retaining spring (E)
down. See F
. 2.
e.
Continue screwing pump into housing
until fluid outlet (D) is aligned with steel
tube and top threads are +/- 1/16 in. (2
mm) of bearing face (N). See F
f.
Tighten locknut (G) by hitting firmly with
a non-sparking hammer. See F
g.
Reconnect fluid inlet (C) and outlet (D).