Operation
307400R
7
Dispensing
To dispense the resin and hardener, turn on the supply
pumps. Then push the handle forward (DOWN) to the
open position. To stop the flow, move the handle to the
UP or closed position.
Fig 3 shows the handle in the DOWN
,
or open
,
posi-
tion
,
sol- vent valve closed
,
and resin and hardener
flowing through the manifold.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Close the mixer fluid valves.
2. Flush the dispensing equipment as described in the
on page 6.
3. Shut off the fluid and solvent pumps.
4. Hold a metal part of the spray gun firmly to a
grounded metal pail, and trigger the gun to relieve
pressure.
5. Engage the gun safety latch
6. Open any drain valves, and leave them open until
you are ready to spray again.
7. If fluid has hardened in the hose or mixer, close the
fluid valve, shut off the fluid and solvent pumps, and
slowly
loosen the fluid inlet hose(s) to relieve pres-
sure, then remove the dispensing hose.
F
IG
. 3
05766
Solvent
Hardener
(B)
(A)
Resin
Solvent
Valve
shown
closed
Handle
down
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief Pro-
cedure when you stop spraying and before cleaning,
checking, or servicing the equipment.
Содержание 241692 A Series
Страница 15: ...Technical Specifications 307400R 15 ...