14 308993
Daily Gun Care, Flushing, and Cleaning
WARNING
PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of a serious injury whenever you
are instructed to relieve pressure, follow the
Pres-
sure Relief Procedure
on page 10.
1.
Relieve the pressure.
2.
Remove the air cap retaining ring (18), air cap
(14), and spray tip (33).
3.
Disconnect the fluid supply hose (H) and air supply
hose (J) from the gun.
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
ÎÎ
9123A
Fig. 8
H
J
18
14
33
4.
Connect the solvent supply hose (T) to the gun.
9124A
Fig. 9
T
5.
Increase the pressure slowly. Point the gun down
into a grounded metal container, and flush the gun
with solvent until all traces of fluid are removed
from the gun passages.
9126A
Fig. 10
6.
Turn off the solvent supply.
7.
Relieve the pressure.
8.
Disconnect the solvent (T) supply hose from the
gun.
Fig. 11
T