background image

308–664

Rev. A

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS

This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.

Contractor ST Airless Spray Gun

3600 psi (252 bar) MAXIMUM WORKING PRESSURE

Model 238–352, Series A

Includes 

  

 RAC

 DripLess

 Guard, 515 size

SwitchTip

, and 4-finger trigger.

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

COPYRIGHT 1996, GRACO INC.

Graco Inc. is registered to I.S. EN ISO 9001

Model 238–352

Содержание 238-352

Страница 1: ...KEEP FOR REFERENCE Contractor ST Airless Spray Gun 3600 psi 252 bar MAXIMUM WORKING PRESSURE Model 238 352 Series A Includes RAC DripLess Guard 515 size SwitchTip and 4 finger trigger GRACO INC P O B...

Страница 2: ...purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum workin...

Страница 3: ...you stop spraying Follow the Pressure Relief Procedure on page 5 if the spray tip clogs and before cleaning checking or servicing the equipment Tighten all fluid connections before operating the equip...

Страница 4: ...n the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any light switch in the spray area while operating or if fumes are pr...

Страница 5: ...re must be manually relieved to prevent the system from starting or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an i...

Страница 6: ...If adjusting the pressure does not give a good spray pattern follow the Pressure Relief Proce dure on page 5 and then try another tip size 8 Use a full open full close triggering action Hold the gun a...

Страница 7: ...ith Standard Flat Tip and Guard 1 Lock the gun trigger safety open the pressure drain valve CAUTION Never soak the entire gun in solvent Prolonged exposure to solvent can ruin the packings 2 Remove th...

Страница 8: ...and spray tip 3 Start the sprayer and adjust it to the lowest pressure 4 Aim the gun into a grounded metal pail while holding it firmly to the pail Trigger the gun If the fluid emitted is not diffused...

Страница 9: ...Soak and clean the parts 3 Put the pump intake in a grounded pail of water or solvent 4 Start the pump at its lowest pressure 5 Trigger the gun into the original pail When water or solvent appears rel...

Страница 10: ...20 25 ft lb 27 34 N m 4 If the gun handle 6 was removed hand tighten it into the fluid housing 26 it should fit easily 5 Adjust the needle before using the gun Procedure below 6 Be sure the trigger g...

Страница 11: ...ent 4 Remove swivel 15 guard retainer 42 and cushion o ring 43 5 Save guard retainer and cushion o ring 05968 Fig 10 6 12 42 43 15 Reassembly 1 Clean internal thread of handle 6 2 Install guard retain...

Страница 12: ...12 308 664 Parts Drawing 06045 41 40 12 5 42 16 20 18 21 22 23 26 32 37 1 31 33 1 Included with 1 Model 238 352 Series A 1 Purchase separately 1 1 6 43 15 44 17...

Страница 13: ...ENT 1 standard 50 mesh 20 179 763 SPRING 1 21 179 722 SPRING RETAINER color coded blue for standard 50 mesh filter 1 22 179 733 GASKET 1 23 191 244 END CAP 1 26 190 973 FLUID HOUSING 1 31 105 334 LOCK...

Страница 14: ...ds is included with every Graco airless gun 237 859 RACR DripLesst Guard Order SwitchTip separately See your distributor for available sizes 220 222 Standard DripLesst Tip Guard Order flat tip separat...

Страница 15: ...470g Inlet 1 4 npsm m swivel Maximum Material Temperature 120 F 50 C Sound Data Sound Pressure Level 78 dB A Sound Power Level 87 dB A Measured while spraying waterbase paint gravity 1 36 through a 51...

Страница 16: ...uipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable ch...

Отзывы: