background image

Service

308371R

11

Service

If the unit requires more than installation of a service kit,
it is usually quickest and easiest to send the unit to the
Graco distributor for repair or replacement.

Lubricate the Heavy-Duty
Agitator

Lubricate the Air Motor

Install an air line lubricator for automatic air motor
lubrication. Set the lubricator feed rate at 1 drop of oil
per minute for high speed or continuous duty usage. Do
not overfeed oil or exhaust air may become
contaminated. To order a 3/8 in. npt air line lubricator,
order Part Number 214847.

If an air line lubricator is not installed, the air motor must
be manually lubricated every 8 hours. Lubricate the
agitator air motor by placing 10–20 drops of SAE #10
light oil in the motor’s air inlet. Run the agitator for about
30 seconds.

Lubricate the Gear Reducer

Refer to F

IG

. 5, page 12. Remove the oil plug (T) and the

oil level plug (L), drain the oil, and thoroughly flush the
housing with light flushing oil. Refill with Graco oil (part
number 217374) to the proper level.

Afterward, change the oil every six months or 2500
hours of operation (whichever occurs first) under normal

operating conditions. More frequent oil changes are
needed under severe operating conditions or in
atmospheres containing excessive moisture or
abrasives. Contact your Graco distributor.

NOTE:

No oil maintenance is required on models

factory filled with Mobil Glygoyle 460 oil.

Flush the Air Motor

If the motor is sluggish or inefficient, flush it with
non-flammable solvent in a well ventilated area.

The recommended solvent for air motors and lubricated
pumps is Gast Flushing Solvent (Part Number AH255 or
AH255A) or Inhibisol Safety Solvent.

1.

Disconnect the air line and muffler

2.

Add several teaspoons of solvent or spray the
solvent directly into the motor.

3.

Rotate the shaft by hand in both directions for a few
minutes.

4.

Reconnect the air line, and slowly increase the air
pressure until there is no trace of solvent in the
exhaust air.

5.

Re-lubricate the motor with a squirt of light-weight
oil in the chamber.

To reduce the risk of serious bodily injury, including
cuts, amputation of fingers, and splashing in the eyes
or on the skin, always follow the

Pressure Relief

Procedure

(page 6), shut off the agitator, and

disconnect the air line before checking or repairing
the agitator.

NOTICE

To prevent air motor failure and possible damage to
the agitator assembly, always keep the air motor
properly lubricated.

Do not use kerosene or other flammable solvents to
flush the air motor. Flushing with flammable solvents
could cause fire or explosion and result in serious
injury or property damage.

Do not use kerosene or other flammable solvents to
flush the air motor. Flushing with flammable solvents
could cause fire or explosion and result in serious
injury or property damage.

Содержание 236662

Страница 1: ...suspension of industrial coatings For professional use only 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information and approvals Important Safety Instructions Read all warnin...

Страница 2: ...s Parts List 16 Xtreme Duty Agitator Drive Train 262858 17 Xtreme Duty Agitator Drive Train Parts List 18 Technical Specifications 19 Air Consumption Chart 19 Graco Standard Warranty 20 Models Agitato...

Страница 3: ...potential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gasoli...

Страница 4: ...cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all app...

Страница 5: ...duce the risk of fire and explosion always maintain a minimum of 1 in clearance inside the material drum between rotating agitator parts and any other objects including the drum to prevent sparks from...

Страница 6: ...osition the air motor so it faces away from the air regulator mounting as shown in FIG 3 4 Install the jam nut C below the tank cover Tighten the jam nut firmly to assure a seal between the gasket 17...

Страница 7: ...ll not be placed inside the tank align top of hub G with the lower mark H on the agitator shaft 14 11 Apply low strength sealant to the two setscrews 13 Firmly secure the paddle with the setscrews 12...

Страница 8: ...sition leaving a 0 015 in 0 006 mm clearance gap between the thrust washer and the top of the shaft support Refer to Parts page 15 10 10 and 15 gallon tanks place the lower bearing assembly 2 and 3 on...

Страница 9: ...e street elbow and check the oil level in the reducer housing The oil should never be higher than the oil level plug If necessary drain or add oil until the proper oil level is attained Screw the oil...

Страница 10: ...the needle valve 20 To reduce the risk of serious bodily injury which can result if the tank pressure is not fully relieved always follow the Pressure Relief Procedure page 6 before opening the tank...

Страница 11: ...ributor NOTE No oil maintenance is required on models factory filled with Mobil Glygoyle 460 oil Flush the Air Motor If the motor is sluggish or inefficient flush it with non flammable solvent in a we...

Страница 12: ...til it bottoms out then back it out 0 015 in 0 38 mm Make sure the air motor inlet and outlet face up 4 Apply Loctite Number 222 to the two clamp setscrews 32 Align the setscrews to one side of the sl...

Страница 13: ...t the agitator shaft 14 and install the new shaft 2 Replace the agitator paddle 3 With the agitator shaft 14 pushed up against the washer 15a secure the lower portion of the coupling half 19b to the s...

Страница 14: ...rvice 14 308371R FIG 6 Apply Loctite Number 271 Torque to 160 in lb 18 Ntm Install seals with open spring loaded side toward tank 2 1 5 19a 19b 15b R 9a 2 9 9b 15a 14 6 40 18 1 8 7 14 REF 16 2 33 2267...

Страница 15: ...4 Remove original bolts and replace with 33 Torque to 160 in lbs 18 N m Locate the bottom shoulder of shaft 14 against washer 15 when assembling coupler 19 Items 38 and 39 are not used on the 5 gallon...

Страница 16: ...Includes items 20a to 20f 1 20a 166529 NEEDLE valve 1 20b 166532 NUT packing 1 20c 164698 KNOB packing 1 20d 157628 O RING buna N 1 20e 165722 BODY valve 1 20f 166531 WASHER nylon 1 21 160023 HOSE cou...

Страница 17: ...13 905 904 903 902 901 5 2 2 5 7 915 4 3 3 5 7 5 3 8 7 7 930 929 931 Apply pipe sealant to all non swiveling pipe threads Apply low strength threadlocker Apply blue thread locker Remove four screws fr...

Страница 18: ...G alignment hub 1 911 112760 COUPLING alignment disk TPE 1 912 16P922 BRACKET adapter agitator 1 913 C19209 WASHER lock 8 914 101682 SCREW socket cap head 4 915 181794 GEAR reducer 1 916 16P923 COUPLE...

Страница 19: ...und pressure At no load at maximum rpm 83 4 dB A Under load at 50 rpm 64 0 dB A Sound power At no load at maximum rpm 96 6 dB A Under load at 50 rpm 77 2 dB A Sound pressure measured 3 feet 1 meter fr...