background image

 

FLUID INJECTION HAZARD

Pressure Relief Procedure
To reduce the risk of serious injury, including fluid injec-
tion or splashing in the eyes or on the skin, always
follow this procedure whenever you shut down the sys-
tem and before inspecting, removing, cleaning or serv-
icing this equipment or any part of the system.

1.

Turn off the power supply to the pump.

2.

Trigger the dispensing valve into a waste contain-
er until pressure is fully relieved.

3.

Open any bleed-type master air valves and fluid
drain valves in the system.

4.

Leave the fluid drain valve open until you are
ready to use the system again.

If you suspect the dispensing valve, extension, nozzle,
or coupler is clogged, or that pressure has not been
fully relieved after following all the steps above, very
slowly loosen the coupler or hose end coupling and
allow pressure to be relieved gradually, then loosen the
part completely. Now clear the clog.

Medical Treatment

If any fluid appears to penetrate your skin, get emergency
medical care at once. Do not treat as a simple cut! 
Tell the
doctor exactly what fluid was injected.

NOTE TO PHYSICIAN: Injection into the skin is a traumatic
injury. It is important to treat the injury surgically as soon
as possible.
 Do not delay treatment to research toxicity. Tox-
icity is a concern with some exotic coatings injected directly
into the blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.

Hydraulic Couplers

Taper Nose Hydraulic Coupler 236–168

8000 psi (560 bar) Maximum Working Pressure

Economy Hydraulic Coupler 236–169

2500 psi (175 bar) Maximum Working Pressure
For use with lever action guns only

WARNING

This coupler is designed for use with lever action guns
only. Any other use of the coupler can cause unsafe op-
erating conditions and result in component rupture, which
could cause serious injury, including fluid injection.

Grease Nozzle

Swivel Grease Nozzle 236–184

6000 psi (420 bar) Maximum Working Pressure

Flexible Extension

Flexible Extension

5000 psi (350 bar) Maximum Working Pressure

Part No.

Length

236–170

12 in. (304.8 mm)

236–182

18 in. (457.2 mm)

236–183

30 in. (762.0 mm)

WARNING

To reduce the risk of serious injury, including fluid
injection,

D

Only install a coupler on the hand grip end of the
hose, as shown below. Never install a coupler on the
other end of the hose.

D

Never use the flexible extension without the hand grip
in place.

02191

Install coupler on
thid end ONLY
(
coupler not included)

Hand Grip

High Pressure Adapters

Locking Sleeve Connector 236–188

6000 psi (420 bar) Maximum Working Pressure
For quick connection to taper nose coupler

360

_

 Grease Swivel & Coupler Kit 236–189

6000 psi (420 bar) Maximum Working Pressure

Straight Swivels 236–187

8000 psi (560 bar) Maximum Working Pressure

Z-swivel 236–186

6500 psi (450 bar) Maximum Working Pressure

Low Pressure Adapters

Hydraulic-to-Steel Needle Adapter 236-178

250 psi (18 bar) Maximum Working Pressure
For flush fittings

Hydraulic-to-Push Adapter 236–177

250 psi (18 bar) Maximum Working Pressure
For U-joints and low pressure service

Hydraulic-to-Nylon Needle Adapter 236-179

250 psi (18 bar) Maximum Working Pressure
For removable plugs

90

_

 Lube Adapter 236–180

250 psi (18 bar) Maximum Working Pressure

Sales Offices: Atlanta, Chicago, Detroit, Los Angeles